High-Resolution Power Doppler Using Null Subtraction Imaging
IEEE Transactions on Medical Imaging · 2024-09 · 43 (9) · 3060-3071
DOI: 10.1109/tmi.2024.3383768 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2024-09. Verfasst von Zhengchang Kou und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Brain, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 49-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NCI NIH HHS, NIA NIH HHS.
Abstract (Originalsprache)
To improve the spatial resolution of power Doppler (PD) imaging, we explored null subtraction imaging (NSI) as an alternative beamforming technique to delay-and-sum (DAS). NSI is a nonlinear beamforming approach that uses three different apodizations on receive and incoherently sums the beamformed envelopes. NSI uses a null in the beam pattern to improve the lateral resolution, which we apply here for improving PD spatial resolution both with and without contrast microbubbles. In this study, we used NSI with three types of singular value decomposition (SVD)-based clutter filters and noise equalization to generate high-resolution PD images. An element sensitivity correction scheme was also proposed as a crucial component of NSI-based PD imaging. First, a microbubble trace experiment was performed to evaluate the resolution improvement of NSI-based PD over traditional DAS-based PD. Then, both contrast-enhanced and contrast free ultrasound PD images were generated from the scan of a rat brain. The cross-sectional profile of the microbubble traces and microvessels were plotted. FWHM was also estimated to provide a quantitative metric. Furthermore, iso-frequency curves were calculated to provide a resolution evaluation metric over the global field of view. Up to six-fold resolution improvement was demonstrated by the FWHM estimate and four-fold resolution improvement was demonstrated by the iso-frequency curve from the NSI-based PD microvessel images compared to microvessel images generated by traditional DAS-based beamforming. A resolvability of [Formula: see text] was measured from the NSI-based PD microvessel image. The computational cost of NSI-based PD was only increased by 40 percent over the DAS-based PD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- NIBIB NIH HHS
- NCI NIH HHS
- NIA NIH HHS
- National Institutes of Health
- National Science Foundation
- Beckman Institute Graduate Fellowship and the Beckman Institute Postdoctoral Fellowship
- Beckman Institute Postdoctoral Fellowship
Zitieren
APA
Kou, Z., Lowerison, M. R., You, Q., Wang, Y., Song, P., & Oelze, M. L. (2024). High-Resolution Power Doppler Using Null Subtraction Imaging. IEEE Transactions on Medical Imaging, 43(9), 3060-3071. https://doi.org/10.1109/tmi.2024.3383768
Vancouver
Kou Z, Lowerison MR, You Q, Wang Y, Song P, Oelze ML. High-Resolution Power Doppler Using Null Subtraction Imaging. IEEE Transactions on Medical Imaging. 2024;43(9):3060-3071. doi:10.1109/tmi.2024.3383768
BibTeX
@article{Kou2024,
author = {Kou, Zhengchang and Lowerison, Matthew R and You, Qi and Wang, Yike and Song, Pengfei and Oelze, Michael L},
title = {High-Resolution Power Doppler Using Null Subtraction Imaging},
journal = {IEEE Transactions on Medical Imaging},
year = {2024},
volume = {43},
number = {9},
pages = {3060--3071},
doi = {10.1109/tmi.2024.3383768}
}
EUVIMED