EUVIMEDEUVIMED entdecken
Crossref

Physio-BP: Physiologically-Guided Dual Radar System for Continuous Blood Pressure Estimation

Zhenzhen Cao, Zhi Lu, Yang Hu, Yan Chen

IEEE Transactions on Mobile Computing · 2026-06 · 25 (6) · 7923-7937

DOI: 10.1109/tmc.2025.3646692 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Mobile Computing, 2026-06. Verfasst von Zhenzhen Cao und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous blood pressure (BP) estimation remains a significant challenge in non-contact hemodynamic monitoring, where existing methods struggle to strike a balance between clinical accuracy and usability.We present Physio-BP, a physiologically-guided dual-radar system enabling calibration-free, continuous tracking of systolic (SBP) and diastolic blood pressure (DBP) by integrating spatially resolved vascular dynamics. Unlike conventional single-waveform radar approaches, Physio-BP synchronously captures mechanical signals from the heart and pulse waves from the carotid artery, allowing precise measurement of pulse arrival time (PAT) and inter-beat intervals (IBI). To enhance signal quality, we introduce a novel joint signal selection algorithm that optimizes feature extraction across dual radars, effectively addressing the inherent signal-to-noise ratio (SNR) disparities between the chest and neck monitoring sites. To validate our system, an extensive dataset exceeding 50 hours was collected under diverse conditions, including different seasons, times of day, body postures, and radar devices, ensuring comprehensive coverage. Experimental results on the dataset confirm that Physio-BP enables continuous and precise SBP and DBP tracking, a capability not achieved by current baseline methods, thereby advancing non-contact sensing for hemodynamic monitoring.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Cao, Z., Lu, Z., Hu, Y., & Chen, Y. (2026). Physio-BP: Physiologically-Guided Dual Radar System for Continuous Blood Pressure Estimation. IEEE Transactions on Mobile Computing, 25(6), 7923-7937. https://doi.org/10.1109/tmc.2025.3646692

Vancouver

Cao Z, Lu Z, Hu Y, Chen Y. Physio-BP: Physiologically-Guided Dual Radar System for Continuous Blood Pressure Estimation. IEEE Transactions on Mobile Computing. 2026;25(6):7923-7937. doi:10.1109/tmc.2025.3646692

BibTeX
@article{Cao2026,
  author = {Cao, Zhenzhen and Lu, Zhi and Hu, Yang and Chen, Yan},
  title = {Physio-BP: Physiologically-Guided Dual Radar System for Continuous Blood Pressure Estimation},
  journal = {IEEE Transactions on Mobile Computing},
  year = {2026},
  volume = {25},
  number = {6},
  pages = {7923--7937},
  doi = {10.1109/tmc.2025.3646692}
}
Kostenlos starten →