Structured Visual Measurement and Consistency Correction for Pointer Scale Systems

Zhenyuan Zhao, Jiahao Wang, Qianming Wang, Yongjie Zhai

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 2516418-2516418

DOI: 10.1109/tim.2026.3723445 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Zhenyuan Zhao und 3 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Special Fund for Hebei University Scientific Research Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pointer scale systems are widely used in industrial inspection, power equipment monitoring, and laboratory instrumentation. This article focuses on pointer scale systems with a single pointer and a single linear scale, a common and representative class in practice. For such systems, recovering a quantitative measurement value constrained by the underlying scale structure from image observations is a key task for reliable automatic reading. Existing pipeline-based methods are susceptible to error accumulation, while direct numerical generation approaches lack explicit measurement semantics and consistency constraints. To address these limitations, we reformulate the task as structured visual measurement. We define an intermediate structural representation that describes the measurement configuration of a pointer scale system and build a two-stage structured visual measurement framework (SVMF) on top of it. Stage 1 performs structured visual parsing. Stage 2 corrects structural inconsistencies with the aid of scale value evidence. A deterministic recovery function then produces the final reading. To improve generalization to variations in measurement structure, we further propose a synthetic data construction strategy conditioned on structure and driven by coverage of the measurement space. Experiments show that the default SVMF clearly outperforms the compared open-source baselines on out-of-distribution real data, with an MNAE of 0.0668 and an Acc@0.05 of 74.88 %. The method also exhibits milder degradation under controlled structural shifts and stable behavior under real illumination and pointer position perturbations. Moreover, the explicit structural representation allows structural inconsistencies and potential failure cases in the reading process to be further checked and diagnosed, thereby providing an empirical basis for reliability and risk analysis of the proposed method.

Förderung

  • National Natural Science Foundation of China
  • Special Fund for Hebei University Scientific Research Program

Zitieren

APA

Zhao, Z., Wang, J., Wang, Q., & Zhai, Y. (2026). Structured Visual Measurement and Consistency Correction for Pointer Scale Systems. IEEE Transactions on Instrumentation and Measurement, 75, 2516418-2516418. https://doi.org/10.1109/tim.2026.3723445

Vancouver

Zhao Z, Wang J, Wang Q, Zhai Y. Structured Visual Measurement and Consistency Correction for Pointer Scale Systems. IEEE Transactions on Instrumentation and Measurement. 2026;75:2516418-2516418. doi:10.1109/tim.2026.3723445

BibTeX
@article{Zhao2026,
  author = {Zhao, Zhenyuan and Wang, Jiahao and Wang, Qianming and Zhai, Yongjie},
  title = {Structured Visual Measurement and Consistency Correction for Pointer Scale Systems},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {2516418--2516418},
  doi = {10.1109/tim.2026.3723445}
}