Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Jiangning Pei und 4 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Gefördert von: National Key R&D Program of China, Wuhan University Experiment Technology Project Funding, Guoqing Zhang (School of Integrated Circuits, Wuhan University) for assisting in the experimental data testing..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time 3-D quantification of laser powder bed fusion (LPBF) melt-pool morphology is essential for mechanistic assessment of process stability and defect susceptibility, yet remains challenging under coaxial, long-working-distance constraints. This study presents a compact, single-camera coaxial stereo imaging system enabled by a biprism that forms virtual left–right views on an industrial CMOS sensor, coupled with a learning-based disparity pipeline for time-resolved 3-D reconstruction of melt-pool free-surface topography. The coaxial configuration enables dense depth recovery without active projection. The system achieves a 6.96- $\mu $ m lateral resolution at an approximately 600-mm working distance and a 7.1- $\mu $ m step-height error (1.4 % on a 500- $\mu $ m gauge-block step). Experiments on 316L (30- $\mu $ m layer thickness) span 49 power–speed conditions, with synchronized image acquisition and 3-D reconstruction at 250 fps. The reconstructed topographies yield geometry-derived descriptors (peak height, depression depth, and relative depression fluctuation) that vary systematically with power and speed, supporting interpretation of stable and unstable melt states in $P$ – $V$ space. A representative turnaround sequence is also discussed as a qualitative example of nonstationary melt-pool morphology during scan-direction reversal. The proposed method enables geometry-driven, high-speed 3-D monitoring of LPBF melt-pool morphology and provides quantitative morphology descriptors for defect correlation and future closed-loop control.

Förderung

  • National Key R&D Program of China
  • Wuhan University Experiment Technology Project Funding
  • Guoqing Zhang (School of Integrated Circuits, Wuhan University) for assisting in the experimental data testing.

Zitieren

APA

Pei, J., Li, H., Shen, S., Chen, H., & Okulov, A. (2026). In Situ Coaxial 3-D Monitoring of LPBF Melt Pool by a Compact Biprism-Enabled Stereo Imaging System. IEEE Transactions on Instrumentation and Measurement, 75, 7005512-7005512. https://doi.org/10.1109/tim.2026.3720898

Vancouver

Pei J, Li H, Shen S, Chen H, Okulov A. In Situ Coaxial 3-D Monitoring of LPBF Melt Pool by a Compact Biprism-Enabled Stereo Imaging System. IEEE Transactions on Instrumentation and Measurement. 2026;75:7005512-7005512. doi:10.1109/tim.2026.3720898

BibTeX
@article{Pei2026,
  author = {Pei, Jiangning and Li, Hui and Shen, Shengnan and Chen, Haoyuan and Okulov, Artem},
  title = {In Situ Coaxial 3-D Monitoring of LPBF Melt Pool by a Compact Biprism-Enabled Stereo Imaging System},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {7005512--7005512},
  doi = {10.1109/tim.2026.3720898}
}
Kostenlos starten →