Thermal-Pulse Measurement of Polarity-Dependent Electric Field Distortion in Metallized BOPP Films
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 6005709-6005709
DOI: 10.1109/tim.2026.3720897 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Xinyan Ying und 2 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
Accurate measurement of polarity-dependent electric field distortion in micrometer-scale metallized polymer films is essential for evaluating dielectric reliability in power capacitors. In this work, a thermal pulse method (TPM)-based measurement protocol is developed to quantitatively characterize polarity-dependent electric field behavior in metallized biaxially oriented polypropylene (BOPP) films under stepwise direct current (DC) electric-field loading. The proposed protocol integrates controlled polarity switching, multilevel field stressing, and calibrated electric-field reconstruction, enabling reproducible comparison of electric field distortion and residual field characteristics under opposite voltage polarities. The measured electric-field profiles exhibit pronounced polarity asymmetry in charge injection onset and field distortion evolution, which is quantified using electric field distortion rate and residual electric field magnitude. Under positive polarity voltage, electric field distortion emerges at lower applied fields and increases more rapidly with field level, whereas under negative polarity voltage, the onset of distortion is delayed and the maximum distortion remains comparatively lower under identical stressing conditions. At an applied electric field of 240 V/ $\mu $ m, the maximum electric-field distortion rates reach 120.8 % and 38.3 % under positive and negative polarities, respectively. These results demonstrate that the proposed TPM-based protocol provides a robust and quantitative measurement approach for resolving polarity-dependent interfacial electric field distortion in micrometer-scale metallized polymer films, offering direct experimental insight into electrode–dielectric interactions relevant to the reliability assessment of DC capacitor insulation systems.
Zitieren
APA
Ying, X., Zheng, F., & Li, J. (2026). Thermal-Pulse Measurement of Polarity-Dependent Electric Field Distortion in Metallized BOPP Films. IEEE Transactions on Instrumentation and Measurement, 75, 6005709-6005709. https://doi.org/10.1109/tim.2026.3720897
Vancouver
Ying X, Zheng F, Li J. Thermal-Pulse Measurement of Polarity-Dependent Electric Field Distortion in Metallized BOPP Films. IEEE Transactions on Instrumentation and Measurement. 2026;75:6005709-6005709. doi:10.1109/tim.2026.3720897
BibTeX
@article{Ying2026,
author = {Ying, Xinyan and Zheng, Feihu and Li, Jiachen},
title = {Thermal-Pulse Measurement of Polarity-Dependent Electric Field Distortion in Metallized BOPP Films},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {6005709--6005709},
doi = {10.1109/tim.2026.3720897}
}