An Integrated GUM–MCM Framework for Estimating CMCs for Anemometer Calibration in Wind Tunnel

M. H. Raouadi, S. Thamri, O. Touayar, W. Dimassi

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 1007017-1007017

DOI: 10.1109/tim.2026.3718082 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von M. H. Raouadi und 3 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Given the complexity of anemometer calibration and the lack of published standards in this field, most laboratories use sophisticated and expensive measurement techniques to ensure low uncertainties. The aim of this work is the development of a low-cost anemometer calibration system with reliable and efficient calibration measurement capabilities (CMCs). Thus, a novel experimental setup and first comprehensive guide to the expression of uncertainty in measurement (GUM)–Monte Carlo method (MCM) framework were developed. Our facility is based on a Göttinger-type wind tunnel, NPL pitot-static tube, and flow calculation system. A new methodology for the identification of appropriate positions for the reference and the device under test (DUT) was carried out, taking into account the blockage effect and all other measurement perturbations. Next, the total uncertainty budget of the reference measurement was estimated, considering all sources of uncertainty, and by developing an advanced mathematical model in accordance with GUM recommendations. Then, a simple and adaptive MCM algorithm was programmed to validate the analytical model according to GUM S1. The adopted CMCs have been confirmed by interlaboratory comparison and ILAC/MRA ISO 17025 accreditation for the wind speed range of 0.8–35 m/s, with expanded uncertainties ~1 %. This provides an efficient, robust, accurate, and low-cost anemometer calibration system for most wind speed sensor models, offering an economical alternative to laser Doppler anemometer (LDA) systems.

Zitieren

APA

Raouadi, M. H., Thamri, S., Touayar, O., & Dimassi, W. (2026). An Integrated GUM–MCM Framework for Estimating CMCs for Anemometer Calibration in Wind Tunnel. IEEE Transactions on Instrumentation and Measurement, 75, 1007017-1007017. https://doi.org/10.1109/tim.2026.3718082

Vancouver

Raouadi MH, Thamri S, Touayar O, Dimassi W. An Integrated GUM–MCM Framework for Estimating CMCs for Anemometer Calibration in Wind Tunnel. IEEE Transactions on Instrumentation and Measurement. 2026;75:1007017-1007017. doi:10.1109/tim.2026.3718082

BibTeX
@article{Raouadi2026,
  author = {Raouadi, M. H. and Thamri, S. and Touayar, O. and Dimassi, W.},
  title = {An Integrated GUM–MCM Framework for Estimating CMCs for Anemometer Calibration in Wind Tunnel},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {1007017--1007017},
  doi = {10.1109/tim.2026.3718082}
}
Kostenlos starten →