EUVIMEDEUVIMED entdecken
Crossref

Axial Ratio Alignment: A Critical Factor for Polarization Purity and Accuracy in 24 GHz Circularly-Polarized Doppler Radar for Vital Sign Monitoring

Mostafa HosseinpourNiari, Zahra Ghattan Kashani

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 4012216-4012216

DOI: 10.1109/tim.2026.3716485 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Mostafa HosseinpourNiari und 1 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article investigates the influence of circular polarization (CP) purity and alignment on the accuracy of radar-based vital sign monitoring (VSM). While CP antennas are widely employed to enhance signal stability, the quantitative relationship between polarization purity, polarization handedness, and the accuracy of heart rate (HR) and respiration rate (RR) estimation remains underexplored. Using a 24-GHz vector network analyzer (VNA)-based Doppler radar system, six antenna configurations with varying polarization characteristics were systematically evaluated through ten repeated measurements per configuration. Statistical analysis using one-way analysis of variance (ANOVA) demonstrates that antenna configuration has a significant effect on HR detection accuracy, whereas RR detection appears statistically insensitive to polarization mismatch. Furthermore, Pearson correlation analysis reveals a strong, statistically significant correlation between polarization loss and HR accuracy, with correlation coefficients ranging from 0.71 to 0.86, indicating that cardiac motion sensing is highly sensitive to polarization purity under the tested conditions. Experimental results show that the same-handed right-hand CP (RHCP) configuration provides the highest performance with a mean HR accuracy of 97.48 %. These findings underscore that reliable HR estimation requires not only appropriate CP handedness but also proper polarization-ellipse alignment and reduced polarization mismatch. This work establishes a framework for optimizing the radar front-end and improving measurement reliability in noncontact physiological sensing.

Zitieren

APA

HosseinpourNiari, M., & Kashani, Z. G. (2026). Axial Ratio Alignment: A Critical Factor for Polarization Purity and Accuracy in 24 GHz Circularly-Polarized Doppler Radar for Vital Sign Monitoring. IEEE Transactions on Instrumentation and Measurement, 75, 4012216-4012216. https://doi.org/10.1109/tim.2026.3716485

Vancouver

HosseinpourNiari M, Kashani ZG. Axial Ratio Alignment: A Critical Factor for Polarization Purity and Accuracy in 24 GHz Circularly-Polarized Doppler Radar for Vital Sign Monitoring. IEEE Transactions on Instrumentation and Measurement. 2026;75:4012216-4012216. doi:10.1109/tim.2026.3716485

BibTeX
@article{HosseinpourNiari2026,
  author = {HosseinpourNiari, Mostafa and Kashani, Zahra Ghattan},
  title = {Axial Ratio Alignment: A Critical Factor for Polarization Purity and Accuracy in 24 GHz Circularly-Polarized Doppler Radar for Vital Sign Monitoring},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {4012216--4012216},
  doi = {10.1109/tim.2026.3716485}
}
Kostenlos starten →