A Handheld Instrument for Intraoperative Measurement of Corneal Stroma Dissection Force in Femtosecond Laser Refractive Surgery
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 4012908-4012908
DOI: 10.1109/tim.2026.3716465 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Honghao Wang und 12 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Postdoctoral Introduction Program of Hubei Province.
Abstract (Originalsprache)
Femtosecond laser refractive surgery is commonly used to correct refractive errors. Manual separation of the laser-cut stromal layer to lift the corneal flap or extract a lenticule is a necessary step during the procedure. Excessive dissection force can compromise surgical quality; thus, the magnitude of the dissection force serves as an important indicator for evaluating the appropriateness of surgical parameters, including laser settings. However, current assessments rely largely on surgeons’ subjective feedback. Currently, no tool exists for real-time, intraoperative quantification of the dissection force, hindering objective evaluation. To address this gap, we developed a compact handheld instrument integrating two S-type load cells and an inertial measurement unit (IMU) to measure dissection forces during corneal stroma separation in femtosecond laser-assisted in situ keratomileusis (FS-LASIK). Experiments on porcine eyes demonstrated that the instrument enables accurate, real-time monitoring of dissection forces. Results revealed that dissection forces are significantly influenced by femtosecond laser parameters, particularly pulse energy. To our knowledge, this study presents the first quantitative measurement of corneal stroma dissection forces during refractive surgery. The instrument establishes a direct, data-driven link between laser settings and mechanical forces, providing a foundation for optimizing surgical protocols, enhancing safety, and standardizing procedures.
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
- Postdoctoral Introduction Program of Hubei Province
Zitieren
APA
Wang, H., Saputra, A. A., Wang, Z., Wang, J., Wang, R., Guo, W., Li, L., Quan, T., Chen, S., Liu, X., Feng, X., Zeng, S., & Lv, X. (2026). A Handheld Instrument for Intraoperative Measurement of Corneal Stroma Dissection Force in Femtosecond Laser Refractive Surgery. IEEE Transactions on Instrumentation and Measurement, 75, 4012908-4012908. https://doi.org/10.1109/tim.2026.3716465
Vancouver
Wang H, Saputra AA, Wang Z, Wang J, Wang R, Guo W, et al. A Handheld Instrument for Intraoperative Measurement of Corneal Stroma Dissection Force in Femtosecond Laser Refractive Surgery. IEEE Transactions on Instrumentation and Measurement. 2026;75:4012908-4012908. doi:10.1109/tim.2026.3716465
BibTeX
@article{Wang2026,
author = {Wang, Honghao and Saputra, Azhar Aulia and Wang, Zuowei and Wang, Jiakang and Wang, Ruoshi and Guo, Weilong and Li, Lianchao and Quan, Tingwei and Chen, Shangbin and Liu, Xiuli and Feng, Xu and Zeng, Shaoqun and Lv, Xiaohua},
title = {A Handheld Instrument for Intraoperative Measurement of Corneal Stroma Dissection Force in Femtosecond Laser Refractive Surgery},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {4012908--4012908},
doi = {10.1109/tim.2026.3716465}
}
EUVIMED