Complex-Domain Acoustic–Pressure Dual-End Measurement Framework for Weak Pipeline Leak Detection
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 2514610-2514610
DOI: 10.1109/tim.2026.3712962 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Weiji Wang und 3 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Liaoning Province, Basic and Applied Basic Research Foundation of Guangdong Province.
Abstract (Originalsprache)
Weak leak detection for long-distance pipelines is challenging. Infrasonic and negative pressure wave (NPW) fluctuations triggered by tiny leaks have very small amplitudes, hindering subtle feature extraction, and these faint signals are easily obscured by pipeline operational adjustments, leading to widespread missed detections. Conventional amplitude thresholding and the independent fusion of acoustic (AC) and NPW signals cannot exploit the inherent phase coupling in raw measurements, impairing weak leak recognition accuracy. This article develops an acoustic-pressure dual-terminal detection framework based on the complex domain consistency transformer (CDCT). First, AC and NPW signals are converted into complex inputs at the early processing stage to preserve cross-modal phase interactions lost in late real-value fusion, facilitating robust detection using phase cues when amplitude information is unreliable. Second, the proposed complex synergy phase concentration (CSPC) metric quantifies windowwise phase coherence and weights attention and temporal aggregation modules; circular statistics are utilized to physically characterize phase consistency and reduce false negatives. Third, bidirectional cross-attention between the upstream and downstream sensor models signals lead-lag patterns and cross-site temporal alignment to further mitigate missed detections. The axial circular variance of intersensor phase differences effectively differentiates normal operation, leakage, and operational disturbance states. Field tests on a 98.6 km buried oil pipeline demonstrate that the proposed method outperforms amplitude thresholding and real-valued Transformer baselines in precision, recall, and missed detection rate.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Liaoning Province
- Basic and Applied Basic Research Foundation of Guangdong Province
Zitieren
APA
Wang, W., Wang, T., Guo, B., & Ma, D. (2026). Complex-Domain Acoustic–Pressure Dual-End Measurement Framework for Weak Pipeline Leak Detection. IEEE Transactions on Instrumentation and Measurement, 75, 2514610-2514610. https://doi.org/10.1109/tim.2026.3712962
Vancouver
Wang W, Wang T, Guo B, Ma D. Complex-Domain Acoustic–Pressure Dual-End Measurement Framework for Weak Pipeline Leak Detection. IEEE Transactions on Instrumentation and Measurement. 2026;75:2514610-2514610. doi:10.1109/tim.2026.3712962
BibTeX
@article{Wang2026,
author = {Wang, Weiji and Wang, Tianbiao and Guo, Biao and Ma, Dazhong},
title = {Complex-Domain Acoustic–Pressure Dual-End Measurement Framework for Weak Pipeline Leak Detection},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {2514610--2514610},
doi = {10.1109/tim.2026.3712962}
}