EUVIMEDEUVIMED entdecken
Crossref

Impact of Tap and Phase-Shifting Designs on Ranging Precision of Indirect Time-of-Flight Sensors

Zhaoxiang Jiang, Wanqiang Li, Kang An, Jindong Tian, Xuan Ma

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 9528209-9528209

DOI: 10.1109/tim.2026.3709354 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Zhaoxiang Jiang und 4 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Amplitude-modulated continuous-wave (AMCW) indirect time-of-flight (ITOF) is a prevalent optical 3-D measurement technology that indirectly measures distance by extracting the phase delay of reflected light via tap circuits. Despite the development of numerous ITOF sensors with varied tap and phase-shifting designs, systematic research on the impact of such designs on ranging precision remains insufficient. Under the constraint of unit received energy, we analyzed the effects of three dominant noise sources—signal light, ambient light, and dark noise—on the ranging precision of mainstream 2-Tap-2M-Phase (where M $\geq $ 2) and N-Tap-N-Phase (where N $\geq $ 3) ITOF sensors, while considering practical factors including nonideal optical waveform, systematic error correction, and limited demodulation contrast. For the 2-Tap-2M-Phase design, phase errors induced by the signal light and ambient light remain essentially unchanged as M varies, while the dark noise-induced phase error increases with M. For the N-Tap-N-Phase design, signal light and ambient light phase errors decrease with N, though dark noise-induced error also rises. Comparative analysis confirms that the N-Tap-N-Phase design better mitigates total phase errors from the three noise sources, outperforming the 2-Tap-2M-Phase design. Experiments with 2-Tap and 4-Tap ITOF sensors confirm our theoretical analyses. Notably, our findings demonstrate that the 4-Tap-4-Phase design reduces the variance of phase errors to half that of the 2-Tap-4-Phase design. This study clarifies the critical impact of tap and phase-shifting designs on ranging precision, providing a reference for existing ITOF sensor selection and guidance for ITOF sensor design optimization.

Förderung

  • National Natural Science Foundation of China
  • Basic and Applied Basic Research Foundation of Guangdong Province

Zitieren

APA

Jiang, Z., Li, W., An, K., Tian, J., & Ma, X. (2026). Impact of Tap and Phase-Shifting Designs on Ranging Precision of Indirect Time-of-Flight Sensors. IEEE Transactions on Instrumentation and Measurement, 75, 9528209-9528209. https://doi.org/10.1109/tim.2026.3709354

Vancouver

Jiang Z, Li W, An K, Tian J, Ma X. Impact of Tap and Phase-Shifting Designs on Ranging Precision of Indirect Time-of-Flight Sensors. IEEE Transactions on Instrumentation and Measurement. 2026;75:9528209-9528209. doi:10.1109/tim.2026.3709354

BibTeX
@article{Jiang2026,
  author = {Jiang, Zhaoxiang and Li, Wanqiang and An, Kang and Tian, Jindong and Ma, Xuan},
  title = {Impact of Tap and Phase-Shifting Designs on Ranging Precision of Indirect Time-of-Flight Sensors},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {9528209--9528209},
  doi = {10.1109/tim.2026.3709354}
}
Kostenlos starten →