Passive Mechanoluminescent Fiber Pressure Sensor Based on Archimedean Spiral Microfiber
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 9526808-9526808
DOI: 10.1109/tim.2026.3706196 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Xiufang Wang und 10 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Natural Science Foundation of Heilongjiang Province of China.
Abstract (Originalsprache)
Passive mechanoluminescent (ML) fiber pressure sensing enables electrically decoupled pressure measurement, but its performance is limited by the tradeoff between mechanical durability and photon collection efficiency. This work presents a passive ML fiber pressure measurement system (PMPS) by integrating an Archimedean spiral microfiber with a pyramid-structured ZnS:Cu@Al2O3/PDMS ML film. The spiral geometry constructs a two-dimensionally distributed photon collection path within a limited sensing area, improving the spatial matching between localized ML emission and the fiber trajectory, reducing the average emission-to-fiber distance, and mitigating stress localization. Under identical material, excitation, and detection conditions, the spiral configuration achieves a 30.2 % higher photon count than the straight fiber configuration. A length-matched trajectory-driven model predicts a 29.46 % enhancement, indicating that the improvement mainly originates from spatial photon collection path optimization, with curvature-assisted coupling treated as a possible auxiliary contribution. The PMPS exhibits an exponential response over 0–60 N, a linear range of 0–6 N, response/recovery times of 130/90 ms, and stable operation over 10 000 cycles. Handwritten digit recognition demonstrates its capability for trajectory-dependent ML signal encoding.
Förderung
- Natural Science Foundation of Heilongjiang Province of China
Zitieren
APA
Wang, X., Wang, S., Jiang, C., Sun, Y., Cong, Z., Yan, W., Liu, Y., Li, M., Guo, M., Shi, B., & Ma, Y. (2026). Passive Mechanoluminescent Fiber Pressure Sensor Based on Archimedean Spiral Microfiber. IEEE Transactions on Instrumentation and Measurement, 75, 9526808-9526808. https://doi.org/10.1109/tim.2026.3706196
Vancouver
Wang X, Wang S, Jiang C, Sun Y, Cong Z, Yan W, et al. Passive Mechanoluminescent Fiber Pressure Sensor Based on Archimedean Spiral Microfiber. IEEE Transactions on Instrumentation and Measurement. 2026;75:9526808-9526808. doi:10.1109/tim.2026.3706196
BibTeX
@article{Wang2026,
author = {Wang, Xiufang and Wang, Shuyue and Jiang, Chunlei and Sun, Yu and Cong, Zhicheng and Yan, Weijie and Liu, Yang and Li, Mingjie and Guo, Minfei and Shi, Bicheng and Ma, Yiming},
title = {Passive Mechanoluminescent Fiber Pressure Sensor Based on Archimedean Spiral Microfiber},
journal = {IEEE Transactions on Instrumentation and Measurement},