Signal Analysis of Solenoid Valve Displacement Anomalies Measured by Eddy-Current Displacement Sensors
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 9527115-9527115
DOI: 10.1109/tim.2026.3706159 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Haonan Wang und 4 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Foundation Item: Integrated Verification of Marine Low-Carbon and Zero-Carbon Low-Speed Engine Technology.
Abstract (Originalsprache)
In high-intensity magnetic field environments, anomalous spike signals detected by eddy-current displacement sensors during solenoid valve displacement monitoring affect measurement accuracy. This study investigates these anomalies through Maxwell–Simplorer cosimulations, spatial orthogonality vertical decoupling experiments, and immobilized-armature dynamic comparison experiments. A unified quantitative model is proposed, characterizing the total measurement deviation as a deterministic superposition of current-driven magnetic flux transients and motion-induced interference components. Within the excitation current range of 40–60 A, the total equivalent spike error increases from 0.125 to 0.193 mm, representing 19.3 % of the 1.0-mm full-scale range. Under the specific conditions of a 60-A driving current and a 1.2-m/s peak velocity, the motional error contributes 0.125 mm to the total equivalent spike error, indicating that it is a main contributor to the observed signal anomalies. This study provides an analytical basis for error analysis and suggests an engineering-layout optimization strategy, in which the axial distance between the sensor probe and the solenoid-coil center is increased to reduce leakage-flux coupling.
Förderung
- Foundation Item: Integrated Verification of Marine Low-Carbon and Zero-Carbon Low-Speed Engine Technology
Zitieren
APA
Wang, H., Fan, Y., Guo, J., Xie, L., & Yang, J. (2026). Signal Analysis of Solenoid Valve Displacement Anomalies Measured by Eddy-Current Displacement Sensors. IEEE Transactions on Instrumentation and Measurement, 75, 9527115-9527115. https://doi.org/10.1109/tim.2026.3706159
Vancouver
Wang H, Fan Y, Guo J, Xie L, Yang J. Signal Analysis of Solenoid Valve Displacement Anomalies Measured by Eddy-Current Displacement Sensors. IEEE Transactions on Instrumentation and Measurement. 2026;75:9527115-9527115. doi:10.1109/tim.2026.3706159
BibTeX
@article{Wang2026,
author = {Wang, Haonan and Fan, Yu and Guo, Jingying and Xie, Liangtao and Yang, Jianguo},
title = {Signal Analysis of Solenoid Valve Displacement Anomalies Measured by Eddy-Current Displacement Sensors},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {9527115--9527115},
doi = {10.1109/tim.2026.3706159}
}