Risk-Aware Measurement Synchronization and Recovery for DSSE With Heterogeneous Data Sources

Md. Zahidul Islam, Yiyun Yao, Yuzhang Lin, Shamsun Nahar Edib, Fei Ding

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 9006215-9006215

DOI: 10.1109/tim.2026.3706155 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Md. Zahidul Islam und 4 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Gefördert von: National Laboratory of the Rockies (NLR) for the U.S. Department of Energy (DOE) under Contract DE{-}, NRL is Provided by the U.S. Department of Energy (DOE), operated under Contract, U.S. Department of Energy Office of Critical Minerals and Energy Innovation Solar Energy Technologies Office.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Power distribution systems are increasingly integrating heterogeneous sensors with varying data reporting rates and types, which pose challenges to achieving observability at the desired temporal resolution of distribution system state estimation (DSSE). Multisensor failures caused by extreme events exacerbate these issues, introducing substantial uncertainties into DSSE. This article proposes a novel solution to these challenges by ensuring high-resolution system observability despite heterogeneous data sources and multisensor failures. First, a deep learning architecture combining long short-term memory (LSTM) and graph convolutional network (GCN) is employed to synchronize meters with different reporting rates, aiming to achieve system observability. A random-walk-model-based approach is introduced to generate pseudo-measurements while properly characterizing their uncertainties under multisensor failures. Finally, a disaster-risk-informed observability metric (RiOM) is defined to quantify the uncertainty associated with state estimation results. The proposed framework offers deeper insights into the system observability on the fly compared with conventional analysis. The effectiveness of the framework is demonstrated on an IEEE standard test case and a large-scale real-world distribution feeder in mid-Minnesota in the U.S.

Förderung

  • National Laboratory of the Rockies (NLR) for the U.S. Department of Energy (DOE) under Contract DE{-}
  • NRL is Provided by the U.S. Department of Energy (DOE), operated under Contract
  • U.S. Department of Energy Office of Critical Minerals and Energy Innovation Solar Energy Technologies Office
  • National Science Foundation

Zitieren

APA

Islam, M. Z., Yao, Y., Lin, Y., Edib, S. N., & Ding, F. (2026). Risk-Aware Measurement Synchronization and Recovery for DSSE With Heterogeneous Data Sources. IEEE Transactions on Instrumentation and Measurement, 75, 9006215-9006215. https://doi.org/10.1109/tim.2026.3706155

Vancouver

Islam MZ, Yao Y, Lin Y, Edib SN, Ding F. Risk-Aware Measurement Synchronization and Recovery for DSSE With Heterogeneous Data Sources. IEEE Transactions on Instrumentation and Measurement. 2026;75:9006215-9006215. doi:10.1109/tim.2026.3706155

BibTeX
@article{Islam2026,
  author = {Islam, Md. Zahidul and Yao, Yiyun and Lin, Yuzhang and Edib, Shamsun Nahar and Ding, Fei},
  title = {Risk-Aware Measurement Synchronization and Recovery for DSSE With Heterogeneous Data Sources},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {9006215--9006215},
  doi = {10.1109/tim.2026.3706155}
}