EUVIMEDEUVIMED entdecken
Crossref

Printed Liquid-Metal Sensor for Robust Wearable Pulse-Wave Monitoring

Yingjie Gao, Zhengyan Wang, Jinxing Wang, Xinxin Chang, Qian Li, Hongbo Wang

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 9526509-9526509

DOI: 10.1109/tim.2026.3705060 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Yingjie Gao und 5 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Talent Introduction Program of Chinese Academy of Sciences, Major Project of Anhui Provincial Science and Technology Innovation Breakthrough Plan.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Soft wearable pressure sensors hold great promise for continuous healthcare monitoring and early disease diagnosis. However, fabricating soft devices that are simultaneously sensitive, accurate, and environmentally stable under real-world conditions remains a significant challenge. In this article, we present an ultrasensitive, robust liquid-metal-based pressure sensor featuring a double-layer cross-channel structure and a microbump array. The microbumps effectively localize and concentrate applied pressure onto the microchannel cross points. This structural synergy significantly amplifies the strain transferred to the liquid-metal channels, thereby substantially enhancing the overall pressure sensitivity. Furthermore, a $10\times 10$ sensing array is configured into a single mechanically integrated network by connecting the liquid-metal lines in series at the periphery. This unique architecture renders the sensor completely position-insensitive, making it an ideal soft pad for alignment-free pulse-wave monitoring. Exhibiting an exceptionally low detection limit of 0.1 mN, the proposed sensor effectively captures weak physiological signals, including capillary pulse waves at the fingertip. The sensor demonstrated excellent environmental adaptability during a 75-min continuous monitoring test simulating sweaty conditions, thereby validating its practical viability. Ultimately, this design overcomes a major obstacle in wearable technology, providing highly reliable, position-insensitive pulse detection, facilitating alignment-free pulse monitoring in diverse practical applications.

Förderung

  • National Natural Science Foundation of China
  • Talent Introduction Program of Chinese Academy of Sciences
  • Major Project of Anhui Provincial Science and Technology Innovation Breakthrough Plan
  • Fundamental Research Funds for the Central Universities
  • Starting Grant from the University of Science and Technology of China

Zitieren

APA

Gao, Y., Wang, Z., Wang, J., Chang, X., Li, Q., & Wang, H. (2026). Printed Liquid-Metal Sensor for Robust Wearable Pulse-Wave Monitoring. IEEE Transactions on Instrumentation and Measurement, 75, 9526509-9526509. https://doi.org/10.1109/tim.2026.3705060

Vancouver

Gao Y, Wang Z, Wang J, Chang X, Li Q, Wang H. Printed Liquid-Metal Sensor for Robust Wearable Pulse-Wave Monitoring. IEEE Transactions on Instrumentation and Measurement. 2026;75:9526509-9526509. doi:10.1109/tim.2026.3705060

BibTeX
@article{Gao2026,
  author = {Gao, Yingjie and Wang, Zhengyan and Wang, Jinxing and Chang, Xinxin and Li, Qian and Wang, Hongbo},
  title = {Printed Liquid-Metal Sensor for Robust Wearable Pulse-Wave Monitoring},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {9526509--9526509},
  doi = {10.1109/tim.2026.3705060}
}
Kostenlos starten →