Precision Drive Control System for Piezoelectric Dispensing Based on Multistate Feedback and High-Dynamic Displacement Measurement
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 7505210-7505210
DOI: 10.1109/tim.2026.3705059 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Xianwei Qian und 7 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Fujian Provincial Natural Science Foundation of China.
Abstract (Originalsprache)
To achieve high-precision control in piezoelectric jet dispensing, this study proposes a closed-loop drive system that integrates high-dynamic strain sensing with fuzzy adaptive proportional-integral-derivative (PID) control. Addressing the poor droplet consistency inherent in existing commercial drivers—which cannot directly measure plunger displacement and rely solely on open-loop or simple voltage closed-loop control—this study delivers core innovations: First, a high-dynamic displacement measurement method based on strain gauges was designed. By detecting strain in the stress-concentration zone of the displacement-amplification mechanism, plunger displacement is reconstructed in real time with a bandwidth exceeding 1 kHz, delivering superior dynamic response compared with commercial capacitive sensors. Second, using this displacement signal as core feedback alongside voltage and current data, a multistate closed-loop control system was established. Fuzzy adaptive PID algorithms were employed for online parameter tuning to suppress time-varying nonlinearities such as hysteresis and creep in the piezoelectric ceramic. Based on this, high-performance drive hardware was developed, primarily comprising a Class D power amplifier and a fourth-order LC filter. At 120 V/4.8 A output, ripple and nonlinear error were reduced to below 1 %. Experiments demonstrate a step response time of $70~\mu $ s and a transient output current of 11.88 A. In dispensing tests, needle displacement fluctuations decreased from ±5 to $\pm 2.4~\mu $ m, while droplet volume coefficient of variation (CV) decreased from 1.06 % to 0.62 %. This study provides a comprehensive, integrated solution for achieving high-precision piezoelectric drive and microfluidic dispensing.
Förderung
- Fujian Provincial Natural Science Foundation of China
Zitieren
APA
Qian, X., Tang, L., Chen, M., Ni, H., Jing, S., Xie, P., He, G., & Wang, L. (2026). Precision Drive Control System for Piezoelectric Dispensing Based on Multistate Feedback and High-Dynamic Displacement Measurement. IEEE Transactions on Instrumentation and Measurement, 75, 7505210-7505210. https://doi.org/10.1109/tim.2026.3705059
Vancouver
Qian X, Tang L, Chen M, Ni H, Jing S, Xie P, et al. Precision Drive Control System for Piezoelectric Dispensing Based on Multistate Feedback and High-Dynamic Displacement Measurement. IEEE Transactions on Instrumentation and Measurement. 2026;75:7505210-7505210. doi:10.1109/tim.2026.3705059
BibTeX
@article{Qian2026,
author = {Qian, Xianwei and Tang, Lantian and Chen, Mengxue and Ni, Haoyang and Jing, Sancai and Xie, Peiqin and He, Gonghan and Wang, Lingyun},
title = {Precision Drive Control System for Piezoelectric Dispensing Based on Multistate Feedback and High-Dynamic Displacement Measurement},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {7505210--7505210},
doi = {10.1109/tim.2026.3705059}
}