EUVIMEDEUVIMED entdecken
Crossref

Fiber Bragg Grating Sensor Embedded in Terfenol-D Polymer Composite for Broken Bar Fault Detection in Induction Motors

Juan D. Lopez-Vargas, Paulo H. Silva-Pinto, Geraldo Bieler, Regina C. Allil, Marcelo M. Werneck

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 9525412-9525412

DOI: 10.1109/tim.2026.3704181 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Juan D. Lopez-Vargas und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil (CAPES)-Finance Code 001, Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro (FAPERJ)-Carlos Chagas Filho Foundation for Research Support of the State of Rio de Janeiro, SEI Proc….

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rotor bar breakage is a critical failure in large induction motors, where unscheduled shutdowns can lead to costs far exceeding the value of the equipment. Conventional diagnostic methods generally rely on frequency domain analysis, which can overlay faults under varying loads. This study presented a diagnostic approach using a magnetic field sensor based on a fiber Bragg grating (FBG) embedded in a magnetostrictive Terfenol-D/polymer composite with oriented magnetic domains. Designed for environments up to $150~^{\circ }$ C, the sensor was developed to operate within the tight mechanical tolerances of the motor air gap. Unlike traditional techniques, the fault detection strategy focuses primarily on identifying magnetic flux asymmetries in the time domain. Experimental validation was performed on a 4-pole motor, demonstrating that bar breaks induce periodic impulsive transients in the stray magnetic field. These anomalies were identified using the Jarque–Bera (JB) normality test, which functioned as a diagnostic mechanism, detecting deviations from the Gaussian behavior. Integrating this statistical verdict with a threshold and a rotational periodicity filter ensures high diagnostic specificity, making it possible that no false positives were observed in the present set of experimental data. The results confirm that this time-domain approach provides a robust real-time monitoring solution, particularly suitable for predictive maintenance of motors in industrial facilities such as oil refineries.

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil (CAPES)-Finance Code 001
  • Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro (FAPERJ)-Carlos Chagas Filho Foundation for Research Support of the State of Rio de Janeiro, SEI Proc…

Zitieren

APA

Lopez-Vargas, J. D., Silva-Pinto, P. H., Bieler, G., Allil, R. C., & Werneck, M. M. (2026). Fiber Bragg Grating Sensor Embedded in Terfenol-D Polymer Composite for Broken Bar Fault Detection in Induction Motors. IEEE Transactions on Instrumentation and Measurement, 75, 9525412-9525412. https://doi.org/10.1109/tim.2026.3704181

Vancouver

Lopez-Vargas JD, Silva-Pinto PH, Bieler G, Allil RC, Werneck MM. Fiber Bragg Grating Sensor Embedded in Terfenol-D Polymer Composite for Broken Bar Fault Detection in Induction Motors. IEEE Transactions on Instrumentation and Measurement. 2026;75:9525412-9525412. doi:10.1109/tim.2026.3704181

BibTeX
@article{LopezVargas2026,
  author = {Lopez-Vargas, Juan D. and Silva-Pinto, Paulo H. and Bieler, Geraldo and Allil, Regina C. and Werneck, Marcelo M.},
  title = {Fiber Bragg Grating Sensor Embedded in Terfenol-D Polymer Composite for Broken Bar Fault Detection in Induction Motors},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {9525412--9525412},
  doi = {10.1109/tim.2026.3704181}
}
Kostenlos starten →