Ablation Volume Monitoring and Estimation Using 3-D Echo Energy Decorrelation With Region Growing in Catheter-Based Ultrasound Moderate Thermal Therapy

Youjia Sun, Qiang Su, Yaojie Wu, Chengzhi Yang, Qiao Wang, Xipeng Chen, Oleksandr Ponemash, Yunke Liu, Jin Huang, Diya Wang, Chris Diederich

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 4009709-4009709

DOI: 10.1109/tim.2026.3704153 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Youjia Sun und 10 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Plan of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Catheter-based ultrasound (CBUS) moderate thermal therapy can enhance radio sensitization, gene therapy, immunotherapy, and drug delivery or activation. Accurate monitoring and estimation of ablation volumes are essential. However, the sensitivity of current 3-D ultrasound ablation monitoring methods and the accuracy of volume estimation were limited due to minute protein denaturation and small alterations in ultrasound echoes within target tissues in CBUS moderate thermal therapy. Therefore, this study proposes 3-D echo energy decorrelation with a region growing (EED-RG) method to address these challenges, of which the feasibility and performance were validated via ex vivo ablation and imaging experiments with varying therapy powers of 8, 10, 12 W and durations of 3–15 min. Compared with the ground truth, the accuracy of ablation volumes, quantified by the Pearson correlation coefficient, estimated by 3-D EED-RG was up to 0.993, and its root mean square error (RMSE) was as low as $0.09~\pm ~0.03$ cm3. Compared to the current methods, EED-RG significantly reduced the RMSE by 16.7 %. This work provides a reliable and precise tool for high-precision 3-D ablation volume monitoring in CBUS moderate thermal therapy, thereby offering crucial technical support for enhancing treatment precision.

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Plan of China

Zitieren

APA

Sun, Y., Su, Q., Wu, Y., Yang, C., Wang, Q., Chen, X., Ponemash, O., Liu, Y., Huang, J., Wang, D., & Diederich, C. (2026). Ablation Volume Monitoring and Estimation Using 3-D Echo Energy Decorrelation With Region Growing in Catheter-Based Ultrasound Moderate Thermal Therapy. IEEE Transactions on Instrumentation and Measurement, 75, 4009709-4009709. https://doi.org/10.1109/tim.2026.3704153

Vancouver

Sun Y, Su Q, Wu Y, Yang C, Wang Q, Chen X, et al. Ablation Volume Monitoring and Estimation Using 3-D Echo Energy Decorrelation With Region Growing in Catheter-Based Ultrasound Moderate Thermal Therapy. IEEE Transactions on Instrumentation and Measurement. 2026;75:4009709-4009709. doi:10.1109/tim.2026.3704153

BibTeX
@article{Sun2026,
  author = {Sun, Youjia and Su, Qiang and Wu, Yaojie and Yang, Chengzhi and Wang, Qiao and Chen, Xipeng and Ponemash, Oleksandr and Liu, Yunke and Huang, Jin and Wang, Diya and Diederich, Chris},
  title = {Ablation Volume Monitoring and Estimation Using 3-D Echo Energy Decorrelation With Region Growing in Catheter-Based Ultrasound Moderate Thermal Therapy},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {4009709--4009709},
  doi = {10.1109/tim.2026.3704153}
}
Kostenlos starten →