Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Seung Il Kim und 5 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: National Research Foundation of Korea (NRF) Grant, Ministry of Science and ICT (MSIT) and the Defense Acquisition Program Administration (DAPA) of Republic of Korea, Korea Research Institute of Standards and Science.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The liquid level in tanks is a parameter for ensuring smooth operations, maintaining product quality, and complying with safety and regulatory standards. Several techniques, such as pressure sensors, inductance methods, radar, and ultrasonics, have been developed to estimate liquid levels in tanks; however, conventional techniques require preliminary calibration using baseline data measured at known liquid levels, which are then used to estimate liquid levels in tanks. To address this limitation, this study develops a baseline-free liquid-level estimation technique for in-service liquid tanks using a plate waveguide. The ultrasonic guided waves propagating from a partially immersed plate waveguide were first measured at various liquid levels. Then, the variations in wave velocity and central frequency with liquid levels were observed numerically and experimentally. Based on these observations, a technique for estimating the liquid level was developed using only ultrasonic guided waves measured at three distinctive input frequencies in the partially immersed plate waveguide. The performance of the developed technique was successfully evaluated using numerical simulations and laboratory experiments. The liquid levels were estimated with a maximum error of 0.0014 m under various temperature conditions, demonstrating the potential of the developed technique as an effective and practical solution for liquid-level monitoring in in-service tanks.

Förderung

  • National Research Foundation of Korea (NRF) Grant
  • Ministry of Science and ICT (MSIT) and the Defense Acquisition Program Administration (DAPA) of Republic of Korea
  • Korea Research Institute of Standards and Science
  • Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Climate, Energy and Environment (MCEE) of Republic of Korea

Zitieren

APA

Kim, S. I., Seung, H. M., Park, J. H., Nam, G. R., Lee, Y., & Kwon, O. (2026). Numerical and Experimental Study of Ultrasonic Guided Wave Propagation in Immersed Waveguide for Liquid-Level Estimation. IEEE Transactions on Instrumentation and Measurement, 75, 9702912-9702912. https://doi.org/10.1109/tim.2026.3699747

Vancouver

Kim SI, Seung HM, Park JH, Nam GR, Lee Y, Kwon O. Numerical and Experimental Study of Ultrasonic Guided Wave Propagation in Immersed Waveguide for Liquid-Level Estimation. IEEE Transactions on Instrumentation and Measurement. 2026;75:9702912-9702912. doi:10.1109/tim.2026.3699747

BibTeX
@article{Kim2026,
  author = {Kim, Seung Il and Seung, Hong Min and Park, Jun Hyeong and Nam, Gi Rim and Lee, Yurim and Kwon, Ohjun},
  title = {Numerical and Experimental Study of Ultrasonic Guided Wave Propagation in Immersed Waveguide for Liquid-Level Estimation},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {9702912--9702912},
  doi = {10.1109/tim.2026.3699747}
}
Kostenlos starten →