EUVIMEDEUVIMED entdecken
Crossref

Lightweight Monitoring Method of Transient Power Quality Disturbances Based on Phase-Robust Kurtosis

Xiaolei Hou, Yuanyuan Sun, Jun Ge, Guoliang Zhao, Haijun Liu, Tongxun Wang, Jie Lou

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 1005213-1005213

DOI: 10.1109/tim.2026.3699670 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Xiaolei Hou und 6 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Key Research and Development Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transient power quality disturbances (PQDs) are highly abrupt and destructive; therefore, their reliable monitoring is essential for the secure and stable power system operation. A wide variety of monitoring indices and the full-data upload architecture pose increasing challenges for lightweight monitoring of transient PQDs. Higher order statistics (HOS), especially kurtosis, can effectively capture abrupt waveform changes, making them suitable as unified monitoring indices of multitype transient PQDs. However, traditional kurtosis has reduced monitoring accuracy due to its phase sensitivity. To address this issue, a lightweight monitoring method for transient PQDs based on a phase-robust kurtosis (PRK) index is proposed. This method first introduces kurtosis as a lightweight monitoring index and explains the cause of phase sensitivity from both theory and waveform distribution characteristics. Then, a PRK index is proposed based on a phase-aligned coupling component to eliminate the phase sensitivity and accurately characterize the severity of transient PQDs. In addition, a cloud-edge-end collaborative lightweight monitoring method is developed to clarify the monitoring process of the PRK index, which effectively guides the lightweight acquisition and transmission of monitoring data and supports intelligent analysis. Both simulation and actual measured data demonstrate the significant capability of the proposed method to reduce data volume and improve monitoring accuracy.

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Hou, X., Sun, Y., Ge, J., Zhao, G., Liu, H., Wang, T., & Lou, J. (2026). Lightweight Monitoring Method of Transient Power Quality Disturbances Based on Phase-Robust Kurtosis. IEEE Transactions on Instrumentation and Measurement, 75, 1005213-1005213. https://doi.org/10.1109/tim.2026.3699670

Vancouver

Hou X, Sun Y, Ge J, Zhao G, Liu H, Wang T, et al. Lightweight Monitoring Method of Transient Power Quality Disturbances Based on Phase-Robust Kurtosis. IEEE Transactions on Instrumentation and Measurement. 2026;75:1005213-1005213. doi:10.1109/tim.2026.3699670

BibTeX
@article{Hou2026,
  author = {Hou, Xiaolei and Sun, Yuanyuan and Ge, Jun and Zhao, Guoliang and Liu, Haijun and Wang, Tongxun and Lou, Jie},
  title = {Lightweight Monitoring Method of Transient Power Quality Disturbances Based on Phase-Robust Kurtosis},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {1005213--1005213},
  doi = {10.1109/tim.2026.3699670}
}
Kostenlos starten →