Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Gui Jin und 10 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Foundation of Technology Innovation and Application Development Project of Chongqing Municipality, Natural Science Foundation of Chongqing Municipality, National Natural Science Foundation of China.
Themen: Schlaganfall
Abstract (Originalsprache)
Stroke is a leading cause of mortality and disability worldwide, with rapid diagnosis critical for effective intervention. Conventional imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI) are limited by their size, cost, and unsuitability for bedside or prehospital emergency use. This study presents a novel superparamagnetic iron oxide nanoparticle (SPIO)-based magnetic induction tomography (SPIO-MIT) for noninvasive stroke-tracing imaging. Operating at an ultralow excitation frequency of 3 kHz and a magnetic field strength below 1 mT, the system effectively suppresses background interference from biological tissues while enhancing sensitivity to SPIO distribution. System performance was validated through phantom experiments featuring varied SPIO positions, geometries, and concentration gradients, confirming accurate imaging of SPIOs with negligible response to low-conductivity substances. Complementary in vitro experiments embedding SPIO-blood mixtures in biological tissues demonstrated minimal background interference. In vivo experiments on a rabbit intracerebral hemorrhage (ICH) model further confirmed precise localization of SPIOs injected into the brain, with detection sensitivity down to 1.2 mg of iron and an imaging diameter of 60 mm. In summary, the developed SPIO-MIT system enables sensitive, noninvasive spatial mapping of SPIOs. By combining the high sensitivity of magnetic particle imaging (MPI) with the operational simplicity and biological safety of MIT, SPIO-MIT represents a promising technique for portable, bedside, and prehospital stroke diagnostics.
Förderung
- Foundation of Technology Innovation and Application Development Project of Chongqing Municipality
- Natural Science Foundation of Chongqing Municipality
- National Natural Science Foundation of China
Zitieren
APA
Jin, G., Xia, C., Wang, F., Yan, L., Zhou, C., Liu, S., Wu, Y., Xu, L., Xu, J., Ma, K., & Sun, J. (2026). Low-Frequency Magnetic Induction Tomography for Superparamagnetic Iron Oxide Nanoparticle-Based Stroke Imaging. IEEE Transactions on Instrumentation and Measurement, 75, 4505214-4505214. https://doi.org/10.1109/tim.2026.3699665
Vancouver
Jin G, Xia C, Wang F, Yan L, Zhou C, Liu S, et al. Low-Frequency Magnetic Induction Tomography for Superparamagnetic Iron Oxide Nanoparticle-Based Stroke Imaging. IEEE Transactions on Instrumentation and Measurement. 2026;75:4505214-4505214. doi:10.1109/tim.2026.3699665
BibTeX
@article{Jin2026,
author = {Jin, Gui and Xia, Chuanqian and Wang, Feng and Yan, Lian and Zhou, Chen and Liu, Siqiao and Wu, Yutong and Xu, Lin and Xu, Jia and Ma, Ke and Sun, Jian},
title = {Low-Frequency Magnetic Induction Tomography for Superparamagnetic Iron Oxide Nanoparticle-Based Stroke Imaging},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {4505214--4505214},
doi = {10.1109/tim.2026.3699665}
}
EUVIMED