Angle Error Correction Method for AFM Flatbed Scanner Based on High-Line-Density Grating Calibrator

Zhangning Xie, Liqin Liu, Lihua Lei

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 1004511-1004511

DOI: 10.1109/tim.2026.3697056 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Zhangning Xie und 2 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Shanghai Innovation Action Plan Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The atomic force microscope (AFM) is a cornerstone of nanoscale measurement technology. Its measurement accuracy directly affects the quality of nanofabrication and characterization. This study presents a method for correcting angular errors in planar scanners. The correction method uses a high-line-density angular calibrator. It addresses the common problem of angular coupling errors in AFM systems. The sources of angular inaccuracies—mechanical structural deviations, sensor crosstalk, and environmental interference—are systematically analyzed. An angular error propagation model is established to quantify each source’s contribution to measurement uncertainty. Furthermore, a directly traceable angular calibration approach is proposed. This approach uses a 2-D chromium grating reference material with a periodic structure, a nominal defined value of 212.8 nm, and precisely orthogonal angles. As a result, it enables accurate nanoscale angular measurements. Experimental results show that the correction method greatly reduces angular coupling errors. In the open-loop configuration, the coupling angle drops from 0.305° to a negligible level. In closed-loop mode, it drops from 3.322° to 0.007°. This fulfills the precision requirements of nanometrology. These findings provide a new technical pathway for angular calibration in metrological-grade AFMs. The work has significant implications for enhancing both measurement accuracy and metrological traceability at the nanoscale.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Shanghai Innovation Action Plan Project
  • Shanghai Basic Research Program “Integrated Circuits” Project
  • Key Laboratory of Metrology and Calibration Technology Fund Project

Zitieren

APA

Xie, Z., Liu, L., & Lei, L. (2026). Angle Error Correction Method for AFM Flatbed Scanner Based on High-Line-Density Grating Calibrator. IEEE Transactions on Instrumentation and Measurement, 75, 1004511-1004511. https://doi.org/10.1109/tim.2026.3697056

Vancouver

Xie Z, Liu L, Lei L. Angle Error Correction Method for AFM Flatbed Scanner Based on High-Line-Density Grating Calibrator. IEEE Transactions on Instrumentation and Measurement. 2026;75:1004511-1004511. doi:10.1109/tim.2026.3697056

BibTeX
@article{Xie2026,
  author = {Xie, Zhangning and Liu, Liqin and Lei, Lihua},
  title = {Angle Error Correction Method for AFM Flatbed Scanner Based on High-Line-Density Grating Calibrator},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {1004511--1004511},
  doi = {10.1109/tim.2026.3697056}
}
Kostenlos starten →