EEG–EIT Synchronous Acquisition System: Development and Preliminary Application in Epileptic Seizure Detection
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 4008214-4008214
DOI: 10.1109/tim.2026.3694733 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Wenjing Zhu und 6 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Key Research and Development Program of Shaanxi, Key Research and Development Projects of Shaanxi Province, National Natural Science Foundation of China-General Program.
Abstract (Originalsprache)
To address the need for precise localization of refractory epileptic foci, this study developed a synchronous electroencephalography (EEG)–electrical impedance tomography (EIT) detection system and validated the feasibility and accuracy of using EIT for epileptogenic zone (EZ) localizing. The system utilizes a single set of electrodes to achieve colocated, simultaneous, and same-channel acquisition of impedance and EEG signals. Cross-interference between devices was eliminated through a dual-domain cooperative strategy combining “hardware low-pass” and “software comb” filtering, ensuring the precision of signal acquisition. System performance was systematically evaluated using a kainic acid (KA)-induced epilepsy model in ten adult male Sprague–Dawle rats. Signals were acquired under three conditions: independent acquisition (reference baseline), synchronous acquisition without filtering (interference state), and synchronous acquisition with filtering (postinterference suppression). After filtering, the impedance difference between synchronous and independent EIT recordings was only 0.15% under normal conditions and 0.71% during seizures. The reconstructed EIT images achieved a structural similarity index (SSIM) of 0.97 and a Dice coefficient of 0.80. The filtered EEG signals exhibited high similarity to independently recorded signals, with cosine similarity and correlation coefficients both exceeding 0.80 under both normal and epileptic conditions. Spatial consistency analysis revealed that the average deviation between the centroid of the EZ localized by EIT and that derived from EEG topography was only 0.13 mm, with a mean relative error of 6.37%. Histological examination confirmed that the regions identified by EIT corresponded to areas exhibiting characteristic epileptic neuronal damage. In 80% of seizures, a sustained impedance decrease (7.48% $\pm ~5.339$ %) was observed in the focal region, and the area of decreased impedance gradually expanded during seizure progression. These results demonstrate that the system can reliably acquire multimodal signals, accurately localize epileptic foci, and monitor dynamic impedance changes during seizure activity. This study provides a foundational platform for future research on multimodal fusion-based epilepsy diagnosis and the development of portable neural monitoring devices.
Förderung
- Key Research and Development Program of Shaanxi
- Key Research and Development Projects of Shaanxi Province
- National Natural Science Foundation of China-General Program
- Xijing Hospital Medical Staff Training and Promotion Fund, Interdisciplinary Medical Research Project
- Interdisciplinary Integration Special Project of Air Force Medical University
Zitieren
APA
Zhu, W., Wu, X., Li, W., Chen, C., Yu, X., Shi, X., & Wang, L. (2026). EEG–EIT Synchronous Acquisition System: Development and Preliminary Application in Epileptic Seizure Detection. IEEE Transactions on Instrumentation and Measurement, 75, 4008214-4008214. https://doi.org/10.1109/tim.2026.3694733
Vancouver
Zhu W, Wu X, Li W, Chen C, Yu X, Shi X, et al. EEG–EIT Synchronous Acquisition System: Development and Preliminary Application in Epileptic Seizure Detection. IEEE Transactions on Instrumentation and Measurement. 2026;75:4008214-4008214. doi:10.1109/tim.2026.3694733
BibTeX
@article{Zhu2026,
author = {Zhu, Wenjing and Wu, Xinyu and Li, Weichen and Chen, Cheng and Yu, Xiao and Shi, Xuetao and Wang, Lei},
title = {EEG–EIT Synchronous Acquisition System: Development and Preliminary Application in Epileptic Seizure Detection},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {4008214--4008214},
doi = {10.1109/tim.2026.3694733}
}
EUVIMED