EUVIMEDEUVIMED entdecken
Crossref

Optimized Multifunctional Optical-Fiber Sensor Integrating MZI-FPI Spectra for Simultaneous Salinity-Temperature Measurement

Hongkun Zheng, Kaixuan Fan, Dianzong Hu, Riqing Lv, Yanan Zhang, Yong Zhao

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 7003208-7003208

DOI: 10.1109/tim.2026.3690801 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Hongkun Zheng und 5 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities, Natural Science Foundation of China- Liaoning.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical-based salinity measurement schemes are plagued by salinity-temperature cross-sensitivity, whereas multifunctional optical-fiber sensors based on misaligned splicing can achieve high-sensitivity measurement and salinity-temperature decoupling. However, due to the limited mode-field diameter (MFD) of single-mode optical fiber, sensors based on misaligned splicing impose stringent requirements for high precision in misalignment control. To address this problem, an optimized multifunctional optical-fiber sensor is proposed, where multimode fiber (MMF) with a larger MFD is adopted to enhance the divergence and collection capacity of light, and the Mach–Zehnder interferometer (MZI) and Fabry–Perot interferometer (FPI) are integrated into the same sensing structure to solve the cross-sensitivity problem. The proposed sensing structure is fabricated by misaligned splicing of the MMF, where the MMF provides greater flexibility in misalignment control and releases the fabrication difficulty. The fabrication experiment demonstrates that MZI and FPI spectra can coexist well when the misaligned-splicing range is 60– $64~\mu $ m, and the spectrum intensity is about 10 dB higher than the SMF-based sensor. The performance test results indicate the salinity sensitivities of MZI and FPI spectra are −2.67 and 79.3 nm/‰ (in optical-path difference (OPD) domain), respectively, while their temperature sensitivities are 1.04 and −19.55393 nm/°C (in OPD domain) at a temperature of $20~^{\circ }$ C. The cross-sensitivity between temperature and salinity can be resolved by leveraging the distinct response characteristics of the two spectra. Furthermore, the proposed scheme alleviates the misalignment tolerance and enhances the spectrum intensity, thereby improving the practical applicability of the sensor.

Förderung

  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities
  • Natural Science Foundation of China- Liaoning

Zitieren

APA

Zheng, H., Fan, K., Hu, D., Lv, R., Zhang, Y., & Zhao, Y. (2026). Optimized Multifunctional Optical-Fiber Sensor Integrating MZI-FPI Spectra for Simultaneous Salinity-Temperature Measurement. IEEE Transactions on Instrumentation and Measurement, 75, 7003208-7003208. https://doi.org/10.1109/tim.2026.3690801

Vancouver

Zheng H, Fan K, Hu D, Lv R, Zhang Y, Zhao Y. Optimized Multifunctional Optical-Fiber Sensor Integrating MZI-FPI Spectra for Simultaneous Salinity-Temperature Measurement. IEEE Transactions on Instrumentation and Measurement. 2026;75:7003208-7003208. doi:10.1109/tim.2026.3690801

BibTeX
@article{Zheng2026,
  author = {Zheng, Hongkun and Fan, Kaixuan and Hu, Dianzong and Lv, Riqing and Zhang, Yanan and Zhao, Yong},
  title = {Optimized Multifunctional Optical-Fiber Sensor Integrating MZI-FPI Spectra for Simultaneous Salinity-Temperature Measurement},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {7003208--7003208},
  doi = {10.1109/tim.2026.3690801}
}
Kostenlos starten →