A Robust Real-Time Quantum Sensing System Based on an Ensemble of Nitrogen-Vacancy Centers in Diamond

Yaowu Lei, Feng Zhou, Dong Li, Huangze Ai, Dezhi Chen, Haoliang Hu, Xiaofei Li, Junchang Huang, Chen Zuo

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 1-13

DOI: 10.1109/tim.2026.3682834 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Yaowu Lei und 8 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Science and Technology Project of State Grid Corporation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The nitrogen-vacancy (NV) centers in diamond have exhibited excellent sensing capabilities. By applying the resonance frequency tracking (RFT) method in a closed-loop system, magnetic-field measurements with a wide dynamic range have been demonstrated. However, the previous strategies employ phase-sensitive control signals, which degrade control robustness and reduce tracking rates, thereby impeding real-time measurements. Here, an amplitude–phase joint discrimination strategy is proposed to improve robustness, overcoming the limitations of existing strategies that are sensitive to phase delays in fluorescence signal transmission. Moreover, to improve the tracking speed, a customized device, integrating a fast-response lock-in amplifier (LIA) and a frequency-agile microwave (MW) source, is reported. The LIA achieves a response time as short as $20~\mu $ s, while the MW source reaches a frequency switching time of $1~\mu $ s. The proposed strategy and customized device are implemented and evaluated on an all-fiber quantum current sensing system. Test results show that the system achieves a maximum sampling rate of 20 kHz, with excellent linearity (a linear deviation of 0.37% over the range of 0–120 A) and high accuracy (a measurement error of 0.73% at 80 A), making it promising for a wide range of high-speed quantum measurement scenarios.

Förderung

  • Science and Technology Project of State Grid Corporation of China

Zitieren

APA

Lei, Y., Zhou, F., Li, D., Ai, H., Chen, D., Hu, H., Li, X., Huang, J., & Zuo, C. (2026). A Robust Real-Time Quantum Sensing System Based on an Ensemble of Nitrogen-Vacancy Centers in Diamond. IEEE Transactions on Instrumentation and Measurement, 75, 1-13. https://doi.org/10.1109/tim.2026.3682834

Vancouver

Lei Y, Zhou F, Li D, Ai H, Chen D, Hu H, et al. A Robust Real-Time Quantum Sensing System Based on an Ensemble of Nitrogen-Vacancy Centers in Diamond. IEEE Transactions on Instrumentation and Measurement. 2026;75:1-13. doi:10.1109/tim.2026.3682834

BibTeX
@article{Lei2026,
  author = {Lei, Yaowu and Zhou, Feng and Li, Dong and Ai, Huangze and Chen, Dezhi and Hu, Haoliang and Li, Xiaofei and Huang, Junchang and Zuo, Chen},
  title = {A Robust Real-Time Quantum Sensing System Based on an Ensemble of Nitrogen-Vacancy Centers in Diamond},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {1--13},
  doi = {10.1109/tim.2026.3682834}
}