EUVIMEDEUVIMED entdecken
Crossref

Transmission-Line Anti-Reflection Coating for High-Frequency Ultrasound IC Inspection

Jun Chen, Xin Wang, Jianguo Ma, Yi Quan, Chunlong Fei, Yintang Yang

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 1-7

DOI: 10.1109/tim.2026.3676174 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Jun Chen und 5 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundations of China, Shaanxi Sanqin Talent Special Support Program: Young Top-Notch Talent Project, Xidian University Interdisciplinary Expansion Special Support Program: Frontier Basic Research Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-frequency ultrasound imaging, due to its penetrability and micrometer-level resolution, is a critical modality for nondestructive testing (NDT) of integrated circuit (IC) packaging. However, the substantial acoustic impedance mismatch between the coupling medium (water) and the silicon substrate creates a severe measurement bottleneck: strong surface reflections drastically reduce the energy transmitted into the chip, degrading the signal-to-noise ratio (SNR) and resolution of internal interconnects. To overcome this physical limitation and enhance the measurement capability of scanning acoustic microscopy (SAM), we have designed a precise anti-reflection coating based on the theory of the evolution from electromagnetic transmission lines to acoustic transmission lines. By modeling the acoustic propagation path as an equivalent circuit, we designed and fabricated a three-layer composite structure (Parylene C/Au/Parylene C) specifically optimized for the particular frequency (70 MHz in this study). Experimental validation on commercial IC chips demonstrates that this “instrumentation conditioning” approach significantly improves signal integrity. Specifically, the coating yielded a 52% increase in the amplitude of internal echoes (from 142 to 216 mV). Furthermore, C-scan imaging revealed a 93% average improvement in the mean gradient of internal metal wires across multiple layers, enabling high-fidelity 3-D reconstruction of interconnection structures that were previously indistinguishable from noise. This method offers a robust, low-cost solution to the intrinsic attenuation problem in high-frequency acoustic measurement, significantly extending the detection depth and clarity for IC reliability analysis.

Förderung

  • National Natural Science Foundations of China
  • Shaanxi Sanqin Talent Special Support Program: Young Top-Notch Talent Project
  • Xidian University Interdisciplinary Expansion Special Support Program: Frontier Basic Research Project

Zitieren

APA

Chen, J., Wang, X., Ma, J., Quan, Y., Fei, C., & Yang, Y. (2026). Transmission-Line Anti-Reflection Coating for High-Frequency Ultrasound IC Inspection. IEEE Transactions on Instrumentation and Measurement, 75, 1-7. https://doi.org/10.1109/tim.2026.3676174

Vancouver

Chen J, Wang X, Ma J, Quan Y, Fei C, Yang Y. Transmission-Line Anti-Reflection Coating for High-Frequency Ultrasound IC Inspection. IEEE Transactions on Instrumentation and Measurement. 2026;75:1-7. doi:10.1109/tim.2026.3676174

BibTeX
@article{Chen2026,
  author = {Chen, Jun and Wang, Xin and Ma, Jianguo and Quan, Yi and Fei, Chunlong and Yang, Yintang},
  title = {Transmission-Line Anti-Reflection Coating for High-Frequency Ultrasound IC Inspection},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {1--7},
  doi = {10.1109/tim.2026.3676174}
}
Kostenlos starten →