EUVIMEDEUVIMED entdecken
Crossref

A Fully Portable and Highly Sensitive All-Fiber Quantum Magnetometer

Chaowen Peng, Kaiyan Liu, Feishu Cao, Piwei Tseng, Yue Wen, Ximian Yao, Yuandong Chen, Minghui Du, Lei Chen, Guishi Liu, Yunhan Luo, Yaofei Chen

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 1-8

DOI: 10.1109/tim.2026.3676172 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Chaowen Peng und 11 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangdong Provincial Quantum Science Strategic Initiative, Fundamental and Interdisciplinary Disciplines Breakthrough Plan of the Ministry of Education of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fiber-optic quantum magnetic sensors based on nitrogen-vacancy (NV) centers in diamond offer unique advantages, such as flexible optical path design and high integration, significantly enhancing their potentials for practical deployment. However, existing fiber-based NV magnetometer systems predominantly rely on bulky discrete components and relatively low sensitivity, imposing critical constraints on system miniaturization and field applicability. Here, we report a fully portable all-fiber quantum magnetometer achieving high sensitivity through three compact modules: a sensor probe integrating a conical fiber tip with micrometer-scale diamond structures sandwiched between paired pyramidal magnetic flux concentrators (PMFCs); a control module combining optical and signal processing subsystems with a customized compact microwave lock-in composite module; and a power supply unit. Magnetic and optical simulations reveal synergistic optimization of magnetic concentrators and optical interfaces, providing critical insights for optimizing quantum sensor performance parameters. The integrated system occupies $21\times 16\times 9$ cm3 with 14.9 W total power consumption while demonstrating a sensitivity of $57.12~\pm ~1.15$ pT/Hz ${}^{1/2}$ at 1 Hz. The physical size of the sensing probe is $6.7\times 4.7\times 4.7$ cm3. Field validations in operational elevators and moving vehicles successfully detected sub-100 nT magnetic anomalies with temporal resolution matching target kinematics. This architecture establishes a paradigm for practical NV magnetometer miniaturization, enabling deployable quantum sensing in real-world scenarios.

Förderung

  • National Natural Science Foundation of China
  • Guangdong Provincial Quantum Science Strategic Initiative
  • Fundamental and Interdisciplinary Disciplines Breakthrough Plan of the Ministry of Education of China
  • Basic and Applied Basic Research Foundation of Guangdong Province
  • Fundamental Research Funds for the Central Universities
  • National Innovation and Entrepreneurship Training Program for Undergraduate

Zitieren

APA

Peng, C., Liu, K., Cao, F., Tseng, P., Wen, Y., Yao, X., Chen, Y., Du, M., Chen, L., Liu, G., Luo, Y., & Chen, Y. (2026). A Fully Portable and Highly Sensitive All-Fiber Quantum Magnetometer. IEEE Transactions on Instrumentation and Measurement, 75, 1-8. https://doi.org/10.1109/tim.2026.3676172

Vancouver

Peng C, Liu K, Cao F, Tseng P, Wen Y, Yao X, et al. A Fully Portable and Highly Sensitive All-Fiber Quantum Magnetometer. IEEE Transactions on Instrumentation and Measurement. 2026;75:1-8. doi:10.1109/tim.2026.3676172

BibTeX
@article{Peng2026,
  author = {Peng, Chaowen and Liu, Kaiyan and Cao, Feishu and Tseng, Piwei and Wen, Yue and Yao, Ximian and Chen, Yuandong and Du, Minghui and Chen, Lei and Liu, Guishi and Luo, Yunhan and Chen, Yaofei},
  title = {A Fully Portable and Highly Sensitive All-Fiber Quantum Magnetometer},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {1--8},
  doi = {10.1109/tim.2026.3676172}
}
Kostenlos starten →