A Conformal Neck Radio Frequency Coil for Ultra-Low-Field Magnetic Resonance Imaging
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 1-10
DOI: 10.1109/tim.2026.3674261 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Yamei Dai und 3 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Major Theme Program of Chongqing Municipality, Chongqing Science and Health Joint Project.
Abstract (Originalsprache)
Portable ultra-low-field magnetic resonance imaging (ULF-MRI) has attracted increasing interest due to its compact design and clinical accessibility. However, the low static field strength inherently limits the signal-to-noise ratio (SNR), posing a challenge for high-quality imaging in anatomically complex regions such as the cervical spine. In this work, we propose a dual-channel conformal radio frequency (RF) receiver coil design method based on the inverse boundary element method (IBEM). The proposed method solves for the RF current distribution that matches target magnetic-field patterns and incorporates Tikhonov regularization to improve numerical stability, thereby yielding manufacturable winding trajectories. Based on the derived winding trajectories, we fabricated a prototype conformal coil using 3-D printing, and its performance was evaluated on a custom-built 50-mT ULF-MRI system through water phantom and human experiments. Experimental results demonstrated that the dual-channel coil achieved a higher SNR than the single-channel design in water phantom imaging. Furthermore, the conformal coil outperformed the conventional cylindrical solenoidal coil in both SNR and image homogeneity. In human imaging, the conformal coil significantly enhanced the SNRs of T1- and T2-weighted images, achieving increases of approximately 99.2% and 125.8%, respectively, compared with those obtained with the conventional cylindrical coil. These findings indicate that the proposed conformal RF receiver coil exhibits superior imaging performance and structural adaptability, thereby providing an effective approach for designing RF coils on complex curved surfaces in ULF-MRI.
Förderung
- National Natural Science Foundation of China
- Major Theme Program of Chongqing Municipality
- Chongqing Science and Health Joint Project
- Shenzhen Science and Technology Innovation Commission
Zitieren
APA
Dai, Y., He, J., Wu, J., & Xu, Z. (2026). A Conformal Neck Radio Frequency Coil for Ultra-Low-Field Magnetic Resonance Imaging. IEEE Transactions on Instrumentation and Measurement, 75, 1-10. https://doi.org/10.1109/tim.2026.3674261
Vancouver
Dai Y, He J, Wu J, Xu Z. A Conformal Neck Radio Frequency Coil for Ultra-Low-Field Magnetic Resonance Imaging. IEEE Transactions on Instrumentation and Measurement. 2026;75:1-10. doi:10.1109/tim.2026.3674261
BibTeX
@article{Dai2026,
author = {Dai, Yamei and He, Jiali and Wu, Jiamin and Xu, Zheng},
title = {A Conformal Neck Radio Frequency Coil for Ultra-Low-Field Magnetic Resonance Imaging},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {1--10},
doi = {10.1109/tim.2026.3674261}
}
EUVIMED