Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Yunxin Hu und 3 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Key Program of the Natural Science Foundation of Zhejiang.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The sensitivity limit (minimum measurable displacement) of incoherent optical methods with digital cameras (e.g., photogrammetry with optical flow and digital image correlation) may be exceeded, according to recent studies, through a singular value decomposition (SVD)-based adaptive spatial pixel averaging with natural dithering to overcome the quantization effect, enabling super-sensitivity full-field displacement measurements. Particularly, it was found that the achievable sensitivity limit is constrained by the number of effective spatial pixels used for SVD-based weighted averaging, that is, a large number of spatial pixels is typically required to achieve super-sensitivity. Nevertheless, the spatiotemporal dynamics in this process are not fully understood and quantified. In this study, we theoretically quantify the roles of spatiotemporal samplings and derive the fundamental sensitivity limit of the SVD-based super-sensitivity photogrammetry method using the Cramér–Rao lower bound (CRLB) theory and the uncertainty propagation principle. Specifically, the equivalence between spatial and temporal samplings for the achievable super-sensitivity of the SVD-based method is established; it implies that increasing either the number of spatial pixels or the number of temporal frames for the SVD-based weighted averaging equivalently improves the measurement sensitivity limit. Furthermore, the fundamental sensitivity limit of the SVD-based super-sensitivity photogrammetry method is theoretically derived, as the minimum measurable displacement is found to be $\delta p^{*} \propto \sigma_{n}(1/\sqrt{N_{s}}+1/\sqrt{N_{t}})$ , quantitatively dependent on the number of spatial pixels $N_{s}$ and the number of temporal frames $N_{t}$ for weighted averaging, and the noise level $\sigma _{n}$ in the measurement system. Validations on the principle and derived model are conducted through numerical simulations and laboratory experiments. Overall, this work contributes to a rigorous general formula for the achievable sensitivity limit of the SVD-based super-sensitivity photogrammetry for full-field displacement measurements. In addition, the revealed quantitative spatiotemporal equivalence indicates that spatial and temporal samplings can compensate for each other to achieve super-sensitivity dynamic displacement measurements. Some remaining challenges and required future research are also discussed.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Key Program of the Natural Science Foundation of Zhejiang

Zitieren

APA

Hu, Y., Li, S., Xia, Y., & Yang, Y. (2026). Quantification of Spatiotemporal Equivalence and Fundamental Sensitivity Limit of SVD-Based Super-Sensitivity Full-Field Incoherent Optical Measurements. IEEE Transactions on Instrumentation and Measurement, 75, 1-12. https://doi.org/10.1109/tim.2026.3671904

Vancouver

Hu Y, Li S, Xia Y, Yang Y. Quantification of Spatiotemporal Equivalence and Fundamental Sensitivity Limit of SVD-Based Super-Sensitivity Full-Field Incoherent Optical Measurements. IEEE Transactions on Instrumentation and Measurement. 2026;75:1-12. doi:10.1109/tim.2026.3671904

BibTeX
@article{Hu2026,
  author = {Hu, Yunxin and Li, Shanwu and Xia, Yong and Yang, Yongchao},
  title = {Quantification of Spatiotemporal Equivalence and Fundamental Sensitivity Limit of SVD-Based Super-Sensitivity Full-Field Incoherent Optical Measurements},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {1--12},
  doi = {10.1109/tim.2026.3671904}
}
Kostenlos starten →