EUVIMEDEUVIMED entdecken
Crossref

Highly Sensitive Cholesterol Detection Using β -Cyclodextrin and Graphene Oxide-Enhanced Surface Plasmon Resonance Sensor

Xuegang Li, Jiaqi Zhang, Dongqi Yan, Xue Zhou, Fang Wang

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 1-8

DOI: 10.1109/tim.2026.3667332 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Xuegang Li und 4 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Young Elite Scientists Sponsorship Program by China Association for Science and Technology, Fundamental Research Funds for the Central Universities.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article researched a novel cholesterol sensor that leverages the power of reflective surface plasmon resonance (SPR). The sensor’s core principle relies on the highly specific interaction between cholesterol and $\beta $ -cyclodextrin ( $\beta $ -CD). A complex is formed when cholesterol adsorbs onto the $\beta $ -CD molecules on the sensor surface. The measurable refractive index (RI) change on the surface of optical fibers is caused by this complex formation, which translates into a detectable shift in the wavelength of the SPR spectrum. The sensor’s effectiveness is further amplified by incorporating 2-D graphene oxide (GO) as a sensitizing material. This addition significantly enhances the sensor’s sensitivity, reaching an impressive 2910 nm/RIU (RI unit), representing a remarkable 75% improvement compared to its unsensitized counterpart. Meanwhile, the abundant functional groups on the GO surface provide a natural and efficient binding platform for the cholesterol-selective $\beta $ -CD probes. This sensor can detect cholesterol with a concentration of $0.1~\mu $ M, a response time of about 30 s, and a detection limit of 2 nM. In addition, the sensor achieves excellent selectivity for cholesterol in solution, minimizing interference from other biomolecules in solution. The compact size, plug-and-play, and excellent stability of this sensor enable it to perform high-sensitivity cholesterol detection, and it is expected to be used in the future to detect human cholesterol levels.

Förderung

  • National Natural Science Foundation of China
  • Young Elite Scientists Sponsorship Program by China Association for Science and Technology
  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of Liaoning Province

Zitieren

APA

Li, X., Zhang, J., Yan, D., Zhou, X., & Wang, F. (2026). Highly Sensitive Cholesterol Detection Using β -Cyclodextrin and Graphene Oxide-Enhanced Surface Plasmon Resonance Sensor. IEEE Transactions on Instrumentation and Measurement, 75, 1-8. https://doi.org/10.1109/tim.2026.3667332

Vancouver

Li X, Zhang J, Yan D, Zhou X, Wang F. Highly Sensitive Cholesterol Detection Using β -Cyclodextrin and Graphene Oxide-Enhanced Surface Plasmon Resonance Sensor. IEEE Transactions on Instrumentation and Measurement. 2026;75:1-8. doi:10.1109/tim.2026.3667332

BibTeX
@article{Li2026,
  author = {Li, Xuegang and Zhang, Jiaqi and Yan, Dongqi and Zhou, Xue and Wang, Fang},
  title = {Highly Sensitive Cholesterol Detection Using β -Cyclodextrin and Graphene Oxide-Enhanced Surface Plasmon Resonance Sensor},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {1--8},
  doi = {10.1109/tim.2026.3667332}
}
Kostenlos starten →