EUVIMEDEUVIMED entdecken
Crossref

An Antenna Sensor for Noninvasive Blood Glucose Detection Based on Multiloop Complementary Split Ring

Zexiang Lv, Junjie Wang, Huangsen Deng, Ansheng Shao, Zhiwei Gong, Jun Luo, Siqiao Liu, Jiawen Zhong, Shuping Yang, Gen Li, Yujie Chen, Jian Sun

IEEE Transactions on Instrumentation and Measurement · 2025 · 74 · 1-16

DOI: 10.1109/tim.2025.3588928 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2025. Verfasst von Zexiang Lv und 11 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: Natural Science Foundation of Chongqing, Chongqing University of Technology Research and Innovation Team Cultivation Program, Chongqing Special Program for Key Projects in Technological Innovation and Application Development.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microwave noninvasive blood glucose monitoring has garnered significant attention as an emerging technology in recent years. This article presents a novel multiring complementary split-ring resonator (CSRR) antenna sensor designed to enhance detection sensitivity and improve compactness. The proposed antenna sensor exhibits ideal resonances around 1.02, 1.79, and 2.23 GHz. A human forearm tissue simulation model was constructed to analyze the penetration capability and return loss of electromagnetic waves within the tissue at different frequencies under loaded and unloaded conditions. The study included both simulated and experimental validation of blood glucose detection performance. Additionally, three different machine learning regression models were employed to estimate blood glucose concentrations. Results indicate that electromagnetic waves can reach the target layer at various frequency points, and changes in blood glucose concentration result in variations in return loss amplitude and resonance frequency. The highest blood glucose detection sensitivity achieved was 1.29 $\times $ $ {10}^{-3}$ dB/(mg/dL) and 8.58 $\times $ $ {10}^{-3}$ MHz/(mg/dL). The coefficient of determination ( $R^{2}$ ) for the gradient boosting decision tree (GBDT) regression model exceeded 98.2%. These findings suggest that the proposed antenna sensor holds significant potential for applications in the field of diabetes management.

Förderung

  • Natural Science Foundation of Chongqing
  • Chongqing University of Technology Research and Innovation Team Cultivation Program
  • Chongqing Special Program for Key Projects in Technological Innovation and Application Development
  • Chongqing Medical Scientific Research Project
  • Chongqing Graduate Research Innovation Project

Zitieren

APA

Lv, Z., Wang, J., Deng, H., Shao, A., Gong, Z., Luo, J., Liu, S., Zhong, J., Yang, S., Li, G., Chen, Y., & Sun, J. (2025). An Antenna Sensor for Noninvasive Blood Glucose Detection Based on Multiloop Complementary Split Ring. IEEE Transactions on Instrumentation and Measurement, 74, 1-16. https://doi.org/10.1109/tim.2025.3588928

Vancouver

Lv Z, Wang J, Deng H, Shao A, Gong Z, Luo J, et al. An Antenna Sensor for Noninvasive Blood Glucose Detection Based on Multiloop Complementary Split Ring. IEEE Transactions on Instrumentation and Measurement. 2025;74:1-16. doi:10.1109/tim.2025.3588928

BibTeX
@article{Lv2025,
  author = {Lv, Zexiang and Wang, Junjie and Deng, Huangsen and Shao, Ansheng and Gong, Zhiwei and Luo, Jun and Liu, Siqiao and Zhong, Jiawen and Yang, Shuping and Li, Gen and Chen, Yujie and Sun, Jian},
  title = {An Antenna Sensor for Noninvasive Blood Glucose Detection Based on Multiloop Complementary Split Ring},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2025},
  volume = {74},
  pages = {1--16},
  doi = {10.1109/tim.2025.3588928}
}