EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Implementation of a 1 GΩ Star-Mesh Graphene Quantized Hall Array Resistance Standard Network for High Resistance Calibration

Marta Musso, Wei-Chen Lin, Yanfei Yang, Ngoc Thanh Mai Tran, Alireza R. Panna, Cheng-Hsueh Yang, Randolph E. Elmquist, David B. Newell, Chi-Te Liang, Massimo Ortolano, Albert F. Rigosi, Dean G. Jarrett

IEEE Transactions on Instrumentation and Measurement · 2025 · 74 · 1-12

DOI: 10.1109/tim.2025.3581627 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2025. Verfasst von Marta Musso und 11 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CAPSTAN Quantum electrical Italian national capacitance standard, MIUR Progetti di Ricerca di Rilevante Interesse Nazionale (PRIN) Bando 2020.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A $1\,{\text G}\Omega $ star-mesh quantized Hall array resistance standard (QHARS) assembled from 37 individual elements, each exhibiting the quantum Hall effect (QHE), was fabricated and tested. The $1\,{\text G}\Omega $ QHARS has three orders of magnitude fewer elements than a largely series $1\,{\text G}\Omega $ QHARS, which would require approximately 77480 elements. A dual source bridge (DSB), using a nanovolt detector and a modified algorithm using least-squares analysis was used to interpolate a bridge null from five measurement points taken near the null of the linear measurement system. The $1\,{\text G}\Omega $ star-mesh QHARS was used as a standard to calibrate 100 M $\Omega $ , $1\,{\text G}\Omega $ , and 10 G $\Omega $ high resistance standards. The star-mesh measurements agreed within the combined standard uncertainties of the values of these standards based on traditional high resistance scaling from the $i=2$ quantized Hall resistance value of $12906.4037...\Omega $ , where guarded Hamon transfer standards and DSBs are used to build-up to high resistance ranges from 1 M $\Omega $ standard resistors.

Förderung

  • CAPSTAN Quantum electrical Italian national capacitance standard
  • MIUR Progetti di Ricerca di Rilevante Interesse Nazionale (PRIN) Bando 2020

Zitieren

APA

Musso, M., Lin, W., Yang, Y., Tran, N. T. M., Panna, A. R., Yang, C., Elmquist, R. E., Newell, D. B., Liang, C., Ortolano, M., Rigosi, A. F., & Jarrett, D. G. (2025). Implementation of a 1 GΩ Star-Mesh Graphene Quantized Hall Array Resistance Standard Network for High Resistance Calibration. IEEE Transactions on Instrumentation and Measurement, 74, 1-12. https://doi.org/10.1109/tim.2025.3581627

Vancouver

Musso M, Lin W, Yang Y, Tran NTM, Panna AR, Yang C, et al. Implementation of a 1 GΩ Star-Mesh Graphene Quantized Hall Array Resistance Standard Network for High Resistance Calibration. IEEE Transactions on Instrumentation and Measurement. 2025;74:1-12. doi:10.1109/tim.2025.3581627

BibTeX
@article{Musso2025,
  author = {Musso, Marta and Lin, Wei-Chen and Yang, Yanfei and Tran, Ngoc Thanh Mai and Panna, Alireza R. and Yang, Cheng-Hsueh and Elmquist, Randolph E. and Newell, David B. and Liang, Chi-Te and Ortolano, Massimo and Rigosi, Albert F. and Jarrett, Dean G.},
  title = {Implementation of a 1 GΩ Star-Mesh Graphene Quantized Hall Array Resistance Standard Network for High Resistance Calibration},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2025},
  volume = {74},
  pages = {1--12},
  doi = {10.1109/tim.2025.3581627}
}