EUVIMEDEUVIMED entdecken
Crossref

Probe-Type QEPAS Gas Sensor Based on Graded-Index Fiber Collimator

Mao Kuang, Decao Wu, Qibin Niu, Binbin Luo, Jinzhong Li, Yidong Wan, Xue Zou

IEEE Transactions on Instrumentation and Measurement · 2025 · 74 · 1-8

DOI: 10.1109/tim.2025.3562990 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2025. Verfasst von Mao Kuang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Science and Technology Research Program of Chongqing Municipal Education Commission, Chongqing Natural Science Fund Innovation and Development Joint Fund, Chongqing University of Technology Research and Innovation Team Cultivation Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The quartz-enhanced photoacoustic spectroscopy (QEPAS) gas sensor exhibited high sensitivity and excellent gas selectivity without requiring a long optical path cell, offering cost-effectiveness and ease of miniaturization compared to tunable diode laser absorption spectroscopy (TDLAS), and cavity-enhanced absorption spectroscopy (CEAS) technologies. However, its volume was constrained by the dimensions of the laser collimator and the multireflection optical path, limiting further size reduction. This study employed a fusion splice method to combine single-mode fiber (SMF), coreless fiber (CLF), and graded-index fiber (GIF), developing a graded-index fiber collimator (GRIN-FC) specifically tailored for QEPAS. The collimator featured a diameter of only $125~\mu $ m while achieving an effective collimation distance exceeding 20 mm. This allowed mechanical integration into the acoustic micro-resonator (MR) using a multitube nested coupling method, forming a probe-type structure with dual-MR parallel off-axis alignment and compact dimensions of $16\times 3.5$ mm. This design significantly reduced the sensor volume while maintaining high sensitivity. Experimental results showed that, using water vapor as the target gas with a laser light source at a wavelength of 1392.53 nm and an average optical power of 10 mW, the amplitude of the second harmonic photoacoustic signal generated by this probe was nearly 26 times higher than that of the bare tuning fork off-axis structure and 1.72 times higher than the conventional gradient-index lens collimation single-MR off-axis structure. The probe’s minimum detectable limit (MDL) for water vapor reached 0.73 ppm. Its compact design enhances adaptability to various measurement scenarios, offering considerable application value.

Förderung

  • Science and Technology Research Program of Chongqing Municipal Education Commission
  • Chongqing Natural Science Fund Innovation and Development Joint Fund
  • Chongqing University of Technology Research and Innovation Team Cultivation Program
  • Basic and Applied Research Project of synchronization of Chongqing University of Technology
  • Graduate Student Innovation Program of Chongqing University of Technology

Zitieren

APA

Kuang, M., Wu, D., Niu, Q., Luo, B., Li, J., Wan, Y., & Zou, X. (2025). Probe-Type QEPAS Gas Sensor Based on Graded-Index Fiber Collimator. IEEE Transactions on Instrumentation and Measurement, 74, 1-8. https://doi.org/10.1109/tim.2025.3562990

Vancouver

Kuang M, Wu D, Niu Q, Luo B, Li J, Wan Y, et al. Probe-Type QEPAS Gas Sensor Based on Graded-Index Fiber Collimator. IEEE Transactions on Instrumentation and Measurement. 2025;74:1-8. doi:10.1109/tim.2025.3562990

BibTeX
@article{Kuang2025,
  author = {Kuang, Mao and Wu, Decao and Niu, Qibin and Luo, Binbin and Li, Jinzhong and Wan, Yidong and Zou, Xue},
  title = {Probe-Type QEPAS Gas Sensor Based on Graded-Index Fiber Collimator},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2025},
  volume = {74},
  pages = {1--8},
  doi = {10.1109/tim.2025.3562990}
}
Kostenlos starten →