Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2025. Verfasst von Zhaohui Jiang und 5 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Project of State Key Laboratory of Precision Manufacturing for Extreme Service Performance, Central South University, Hunan Provincial Natural Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Noise interference severely limits the accuracy and stability of gas concentration measurement in direct absorption spectroscopy (DAS). In this article, an end-to-end methane concentration measurement model (EoE-MCMM) consisting of a gas spectrum filter (GSF) and a gas concentration predictor (GCP) is established. The GSF is implemented by deep residual shrinkage network (DRSN) and multilayer perceptron. Based on the advantage of DRSN in effectively processing high-noise data, the GSF can mine effective absorption information from the noisy methane transmission spectrum. In addition, the GCP consists of three fully connected layers, which directly inverts the output spectrum from the GSF. It is worth noting that in the training stage of the GCP, the pretrained weights of the GSF are loaded by transfer learning to accelerate the convergence speed of the GCP module training process. The results show that the proposed GSF outperforms other commonly used filtering methods and improves the signal-to-noise ratio of the experimental data by 10 dB. In terms of concentration prediction, the gas concentration determination coefficient ( $R^{2}$ ) is 99.9%, which is higher than the traditional filtering methods. In addition, the measurement precision of the method is 0.26 ppm by continuous measurement of methane for 1 h, and the limit of detection (LOD) of methane is 0.052 ppm at an integration time of 30 s and 0.008 ppm at an integration time of 400 s according to Allan deviation analysis. These results show that the model provides a more effective, accurate, and convenient solution for DAS gas concentration measurement.

Förderung

  • National Natural Science Foundation of China
  • Project of State Key Laboratory of Precision Manufacturing for Extreme Service Performance, Central South University
  • Hunan Provincial Natural Science Foundation

Zitieren

APA

Jiang, Z., Wu, J., Yu, H., Lan, L., Pan, D., & Gui, W. (2025). End-to-End Methane Concentration Measurement Model With Deep Residual Shrinkage Network for Direct Absorption Spectroscopy. IEEE Transactions on Instrumentation and Measurement, 74, 1-11. https://doi.org/10.1109/tim.2025.3529579

Vancouver

Jiang Z, Wu J, Yu H, Lan L, Pan D, Gui W. End-to-End Methane Concentration Measurement Model With Deep Residual Shrinkage Network for Direct Absorption Spectroscopy. IEEE Transactions on Instrumentation and Measurement. 2025;74:1-11. doi:10.1109/tim.2025.3529579

BibTeX
@article{Jiang2025,
  author = {Jiang, Zhaohui and Wu, Jiahui and Yu, Haoyang and Lan, Lijuan and Pan, Dong and Gui, Weihua},
  title = {End-to-End Methane Concentration Measurement Model With Deep Residual Shrinkage Network for Direct Absorption Spectroscopy},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2025},
  volume = {74},
  pages = {1--11},
  doi = {10.1109/tim.2025.3529579}
}
Kostenlos starten →