Affine Constrained Binocular Camera Calibration With Planar Target Single-Axis Translating
IEEE Transactions on Instrumentation and Measurement · 2024 · 73 · 1-13
DOI: 10.1109/tim.2024.3387493 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2024. Verfasst von Zhao Zheng und 10 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Key Reasearch and Development Program of China, National Science Foundation Program of China.
Abstract (Originalsprache)
Binocular camera is widely used in high-accuracy 3-D measurement and the systematic error is critically determined by the calibration of camera parameters. This article proposes a binocular camera calibration method based on planar target with different orientations translating along single axis. The translation of planar target composes a calibration grid, which is localized in an affine coordinate system (ACS). In addition, nonhomogeneous projection equations of binocular camera indicate the relationship between ACS and image projection coordinate system (IPCS). Therefore, a linear estimation of binocular camera parameters is obtained. In addition, we collect multiple calibration grids with different orientations to improve the estimation accuracy of principal points. Finally, we minimize reprojection error to optimize these camera parameters. Simulation and application experiments demonstrate that our method achieves less focal length error (0.063 pixel) than traditional calibration method using arbitrary placed planar target (0.123 pixel), and less principal point error (0.220 pixel) than pure translation method (0.271 pixel).
Förderung
- National Key Reasearch and Development Program of China
- National Science Foundation Program of China
Zitieren
APA
Zheng, Z., Fan, J., Shao, L., Yang, H., Zhao, L., Song, H., Ai, D., Fu, T., Xiao, D., Wang, Y., & Yang, J. (2024). Affine Constrained Binocular Camera Calibration With Planar Target Single-Axis Translating. IEEE Transactions on Instrumentation and Measurement, 73, 1-13. https://doi.org/10.1109/tim.2024.3387493
Vancouver
Zheng Z, Fan J, Shao L, Yang H, Zhao L, Song H, et al. Affine Constrained Binocular Camera Calibration With Planar Target Single-Axis Translating. IEEE Transactions on Instrumentation and Measurement. 2024;73:1-13. doi:10.1109/tim.2024.3387493
BibTeX
@article{Zheng2024,
author = {Zheng, Zhao and Fan, Jingfan and Shao, Long and Yang, Heqiang and Zhao, Liming and Song, Hong and Ai, Danni and Fu, Tianyu and Xiao, Deqiang and Wang, Yongtian and Yang, Jian},
title = {Affine Constrained Binocular Camera Calibration With Planar Target Single-Axis Translating},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2024},
volume = {73},
pages = {1--13},
doi = {10.1109/tim.2024.3387493}
}
EUVIMED