EUVIMEDEUVIMED entdecken
Crossref

Heart Rate Estimation in Driver Monitoring System Using Quality-Guided Spectrum Peak Screening

Zheng Gong, Xuezhi Yang, Rencheng Song, Xuesong Han, Chong Ren, Hailin Shi, Jianwei Niu, Wei Li

IEEE Transactions on Instrumentation and Measurement · 2024 · 73 · 1-14

DOI: 10.1109/tim.2024.3352710 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2024. Verfasst von Zheng Gong und 7 weiteren Autor:innen. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Hefei University of Technology-NIO Innovation Institute, Collaborative Innovation Project of Colleges and Universities of Anhui Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Remote photoplethysmography (rPPG) enables heart rate (HR) measurement under stable illumination and low noise conditions. However, challenges arise due to rapid lighting changes, significant head movements, and vehicle vibrations during driving, impacting the recovery of clear rPPG signals and rendering denoising techniques alone inadequate in entirely eliminating noise interference. To address these challenges, we introduce an innovative approach, “quality-guided spectrum peak screening” (QSPS), for monitoring the driver’s HR during driving. First, we developed a signal evaluation framework for assessing signal quality across multiple facial regions following wavelet filtering. Subsequently, by leveraging quality information, a spectral peak screening algorithm is applied to signals from multiple regions, mitigating the impact of residual noise on rPPG. The precise HR is determined by integrating quality scores and short-term stability from various facial regions. Our method is employed in a commercially available driver monitoring system (DMS) equipped with a monochrome camera. Test results show QSPS’s robustness compared with established near-infrared (NIR)-based HR detection methods. In driving scenarios, QSPS achieves a mean absolute error (MAE) of 4.32 bpm, a root mean square error (RMSE) of 6.15 bpm, and a percentage of time with HR estimation errors smaller than 6 bpm of 68.8%. Furthermore, QSPS exhibits excellent performance during extended 10-min HR monitoring, with a Pearson correlation coefficient of 0.943 in the night test and 0.906 in the day test.

Förderung

  • Hefei University of Technology-NIO Innovation Institute
  • Collaborative Innovation Project of Colleges and Universities of Anhui Province

Zitieren

APA

Gong, Z., Yang, X., Song, R., Han, X., Ren, C., Shi, H., Niu, J., & Li, W. (2024). Heart Rate Estimation in Driver Monitoring System Using Quality-Guided Spectrum Peak Screening. IEEE Transactions on Instrumentation and Measurement, 73, 1-14. https://doi.org/10.1109/tim.2024.3352710

Vancouver

Gong Z, Yang X, Song R, Han X, Ren C, Shi H, et al. Heart Rate Estimation in Driver Monitoring System Using Quality-Guided Spectrum Peak Screening. IEEE Transactions on Instrumentation and Measurement. 2024;73:1-14. doi:10.1109/tim.2024.3352710

BibTeX
@article{Gong2024,
  author = {Gong, Zheng and Yang, Xuezhi and Song, Rencheng and Han, Xuesong and Ren, Chong and Shi, Hailin and Niu, Jianwei and Li, Wei},
  title = {Heart Rate Estimation in Driver Monitoring System Using Quality-Guided Spectrum Peak Screening},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2024},
  volume = {73},
  pages = {1--14},
  doi = {10.1109/tim.2024.3352710}
}
Kostenlos starten →