Suppression of Amplitude and Phase Errors in Optically Pumped Magnetometers Using Dual-PI Closed-Loop Control

Tengyue Long, Xinda Song, Zhaoxin Duan, Yuchen Suo, Zhendong Wu, Le Jia, Bangcheng Han

IEEE Transactions on Instrumentation and Measurement · 2024 · 73 · 1-12

DOI: 10.1109/tim.2023.3341139 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2024. Verfasst von Tengyue Long und 6 weiteren Autor:innen. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optically pumped magnetometer (OPM) has gained popularity as a viable alternative to the superconducting quantum interference device (SQUID) for biomagnetic measurements. However, the presence of amplitude and phase errors in the OPM can degrade the signal quality of, e.g., magnetoencephalography (MEG) signals. This study presents a dual-PI closed-loop control (DPCC) method aimed at suppressing amplitude and phase errors of the OPM when operated in the spin-exchange relaxation-free (SERF) regime, thereby enhancing MEG localization accuracy. The main sources of the amplitude and phase errors in the OPM are identified through a theoretical analysis of the inertial element characteristics and static residual magnetic fields. The experimental results demonstrate that the utilization of DPCC for the OPM reduces the amplitude and phase errors in static MEG measurements by 94.2% and 95.6%, respectively. At a residual magnetic field of 6.5 nT, the amplitude and phase errors are further suppressed by 97.8% and 87.2%, respectively. Furthermore, the fluctuation of the residual magnetic field is reduced by a factor of 25, significantly enhancing the robustness of the OPM. This straightforward and effective arrangement of the OPM holds promise in the field of biomagnetism and is expected to enhance the localization and calibration accuracy of OPM-based MEG (OPM-MEG) systems.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Long, T., Song, X., Duan, Z., Suo, Y., Wu, Z., Jia, L., & Han, B. (2024). Suppression of Amplitude and Phase Errors in Optically Pumped Magnetometers Using Dual-PI Closed-Loop Control. IEEE Transactions on Instrumentation and Measurement, 73, 1-12. https://doi.org/10.1109/tim.2023.3341139

Vancouver

Long T, Song X, Duan Z, Suo Y, Wu Z, Jia L, et al. Suppression of Amplitude and Phase Errors in Optically Pumped Magnetometers Using Dual-PI Closed-Loop Control. IEEE Transactions on Instrumentation and Measurement. 2024;73:1-12. doi:10.1109/tim.2023.3341139

BibTeX
@article{Long2024,
  author = {Long, Tengyue and Song, Xinda and Duan, Zhaoxin and Suo, Yuchen and Wu, Zhendong and Jia, Le and Han, Bangcheng},
  title = {Suppression of Amplitude and Phase Errors in Optically Pumped Magnetometers Using Dual-PI Closed-Loop Control},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2024},
  volume = {73},
  pages = {1--12},
  doi = {10.1109/tim.2023.3341139}
}
Kostenlos starten →