EUVIMEDEUVIMED entdecken
Crossref

Second-Order Disturbance-Observer-Based Output-Feedback Voltage Control of DC/DC Converters Using Pole-Zero Cancellation

Seok-Kyoon Kim, Chao Xu, Choon Ki Ahn

IEEE Transactions on Industrial Electronics · 2026-09 · 73 (9) · 12905-12917

DOI: 10.1109/tie.2026.3677705 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2026-09. Verfasst von Seok-Kyoon Kim und 2 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Research Foundation of Korea.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The proposed approach establishes an observer-based proportional-integral (PI)-type feedback system structure in which a second-order disturbance observer (SO-DOB) acts as a feed-forward compensator, thereby removing the requirement for the true values of converter parameters and load information. This work offers three main technical contributions. First, a pole-zero cancellation (PZC)-based observer is developed with a specially designed gain structure that diagonalizes the estimation error dynamics in a model-independent manner. Second, the SO-DOB enables robust estimation of disturbances induced by plant-model mismatch and load uncertainty, while simultaneously imposing prescribed second-order closed-loop dynamics. Third, a single-loop PI-type controller integrates the PZC-based observer and the SO-DOB to ensure exponential convergence of the regulation error and critically damped input? output behavior through PZC, without the use of current feedback. Experimental verification on a 3 kW bidirectional converter prototype confirms the practical effectiveness of the proposed controller and demonstrates a 29${\boldsymbol{\%}}$ performance improvement in comparison with a recent method.

Förderung

  • National Natural Science Foundation of China
  • National Research Foundation of Korea

Zitieren

APA

Kim, S., Xu, C., & Ahn, C. K. (2026). Second-Order Disturbance-Observer-Based Output-Feedback Voltage Control of DC/DC Converters Using Pole-Zero Cancellation. IEEE Transactions on Industrial Electronics, 73(9), 12905-12917. https://doi.org/10.1109/tie.2026.3677705

Vancouver

Kim S, Xu C, Ahn CK. Second-Order Disturbance-Observer-Based Output-Feedback Voltage Control of DC/DC Converters Using Pole-Zero Cancellation. IEEE Transactions on Industrial Electronics. 2026;73(9):12905-12917. doi:10.1109/tie.2026.3677705

BibTeX
@article{Kim2026,
  author = {Kim, Seok-Kyoon and Xu, Chao and Ahn, Choon Ki},
  title = {Second-Order Disturbance-Observer-Based Output-Feedback Voltage Control of DC/DC Converters Using Pole-Zero Cancellation},
  journal = {IEEE Transactions on Industrial Electronics},
  year = {2026},
  volume = {73},
  number = {9},
  pages = {12905--12917},
  doi = {10.1109/tie.2026.3677705}
}
Kostenlos starten →