High-Precision Nonlinear Spatial Gradient Disturbance Suppression Method for Magnetic Shielding Cylinder
IEEE Transactions on Industrial Electronics · 2026-02 · 73 (2) · 3316-3327
DOI: 10.1109/tie.2025.3613643 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2026-02. Verfasst von Haifeng Zhang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: National Natural Science Foundation of China, 2022 Industrial Technology Basic Public Service Platform Project.
Abstract (Originalsprache)
High-power devices used in hospitals generate harmonic magnetic field disturbances inside magnetic shielding cylinders (MSCs). These disturbances exhibit axial-gradient spatial distributions, which substantially degrade the imaging quality of magnetocardiography (MCG). To address this issue, a high-precision nonlinear spatial gradient disturbance suppression method is proposed for single-open MSCs. First, a nonlinear gradient coil design is developed to generate variable magnetic field gradients, precisely matching the nonlinear gradient distribution induced by external magnetic disturbances in the MSC. Subsequently, the entire system is modeled, and a composite controller based on proportional-integral repetitive control-linear extended state observer (PIRC-LESO) is designed to enhance the suppression of magnetic field disturbances with harmonic characteristics. Finally, an active magnetic field disturbance suppression system was implemented to evaluate the effectiveness of the nonlinear spatial gradient disturbance suppression method. Experimental results demonstrate that the proposed method reduces the peak-to-peak magnetic field disturbance from 42.0 to 6.9 pT and significantly enhances the signal-to-noise ratio of the MCG signals.
Förderung
- National Natural Science Foundation of China
- 2022 Industrial Technology Basic Public Service Platform Project
Zitieren
APA
Zhang, H., Jing, Z., Zhao, F., Ye, X., Li, S., Lian, Y., & Liu, G. (2026). High-Precision Nonlinear Spatial Gradient Disturbance Suppression Method for Magnetic Shielding Cylinder. IEEE Transactions on Industrial Electronics, 73(2), 3316-3327. https://doi.org/10.1109/tie.2025.3613643
Vancouver
Zhang H, Jing Z, Zhao F, Ye X, Li S, Lian Y, et al. High-Precision Nonlinear Spatial Gradient Disturbance Suppression Method for Magnetic Shielding Cylinder. IEEE Transactions on Industrial Electronics. 2026;73(2):3316-3327. doi:10.1109/tie.2025.3613643
BibTeX
@article{Zhang2026,
author = {Zhang, Haifeng and Jing, Zhongxiang and Zhao, Fengwen and Ye, Xiangyang and Li, Suhang and Lian, Yunyang and Liu, Gang},
title = {High-Precision Nonlinear Spatial Gradient Disturbance Suppression Method for Magnetic Shielding Cylinder},
journal = {IEEE Transactions on Industrial Electronics},
year = {2026},
volume = {73},
number = {2},
pages = {3316--3327},
doi = {10.1109/tie.2025.3613643}
}