Control-Based Distance Protection for Tie Line Between Offshore Wind Farms and MMC During Single-Phase Grounding and Interphase Faults

Zhe Yang, Hongyi Wang, Wenlong Liao, Zhe Chen

IEEE Transactions on Industrial Electronics · 2025-10 · 72 (10) · 10166-10177

DOI: 10.1109/tie.2025.3552188 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2025-10. Verfasst von Zhe Yang und 3 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 37 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Offshore wind farms (OWFs) are often connected to onshore systems via a modular multilevel converter (MMC)-high voltage dc (HVDC) line. However, for the tie line between the OWF and the MMC, the unique fault behaviors will threaten the correct operation of conventional distance relays. Therefore, a coordination scheme between protection and control is proposed in this article. The proposed method can make the distance relay on the OWF terminal be triggered within 0.3 s. After that, the zone I distance relay on the MMC terminal can safeguard the entire line, allowing the fault to be switched off in less than 0.7 s. The proposed method can make the OWF-MMC system compatible with the traditional distance relays, while the overvoltage can be suppressed. Furthermore, the typical fault ride-through (FRT) demands such as current limitation and reactive current injection are still satisfied. In addition, the suggested approach possesses a robust capacity to tolerate fault resistance. These advantages avoid investment in modifying the protection algorithm while effectively protecting the inverter. PSCAD simulation and hardware-in-the-loop (HIL) testing validate its performance under various fault conditions.

Zitieren

APA

Yang, Z., Wang, H., Liao, W., & Chen, Z. (2025). Control-Based Distance Protection for Tie Line Between Offshore Wind Farms and MMC During Single-Phase Grounding and Interphase Faults. IEEE Transactions on Industrial Electronics, 72(10), 10166-10177. https://doi.org/10.1109/tie.2025.3552188

Vancouver

Yang Z, Wang H, Liao W, Chen Z. Control-Based Distance Protection for Tie Line Between Offshore Wind Farms and MMC During Single-Phase Grounding and Interphase Faults. IEEE Transactions on Industrial Electronics. 2025;72(10):10166-10177. doi:10.1109/tie.2025.3552188

BibTeX
@article{Yang2025,
  author = {Yang, Zhe and Wang, Hongyi and Liao, Wenlong and Chen, Zhe},
  title = {Control-Based Distance Protection for Tie Line Between Offshore Wind Farms and MMC During Single-Phase Grounding and Interphase Faults},
  journal = {IEEE Transactions on Industrial Electronics},
  year = {2025},
  volume = {72},
  number = {10},
  pages = {10166--10177},
  doi = {10.1109/tie.2025.3552188}
}