EUVIMEDEUVIMED entdecken
Crossref

Torque Ripple Suppression in the Full Torque Operation Range for Dual Three-Phase PMSM Under Single-Phase Open-Circuit Fault

Zhanqing Zhou, Zhongchen Li, Chenyi Song, Guozheng Zhang, Qiang Geng

IEEE Transactions on Industrial Electronics · 2025-05 · 72 (5) · 4436-4446

DOI: 10.1109/tie.2024.3454474 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2025-05. Verfasst von Zhanqing Zhou und 4 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Tianjin Municipality.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Better fault-tolerant operation performance of dual three-phase permanent magnet synchronous motor (DTPMSM) has always been pursued by both academia and industry. Torque output capability, torque ripple and copper losses are of the three most concerned performance metrics. Optimizing the torque output capability and copper losses of drive in the postfault operation is usually considered simultaneously and have been well addressed, whereas the suppression of torque ripple has not been well studied. In addition, there is a lack of methods that can take into account all three metrics at the same time. Aiming to fill these gaps, this article reveals the cause of torque ripple generated under single-phase open-circuit fault (OCF) and proposes a torque ripple suppression (TRS) scheme without the need of additional controller. Furthermore, this article also reveals the feasibility of improving these metrics at the same time. The proposed TRS scheme is combined with an existing full-range minimum copper loss scheme using a multireference frame harmonic subspace controller, which allows for taking care of all the three metrics mentioned above. The proposed scheme has the same control structure as in normal operation, so it is highlighted with the features of minimum reconfiguration and easy implementation. The effectiveness of the proposed strategy is verified by a large number of experimental results.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Tianjin Municipality

Zitieren

APA

Zhou, Z., Li, Z., Song, C., Zhang, G., & Geng, Q. (2025). Torque Ripple Suppression in the Full Torque Operation Range for Dual Three-Phase PMSM Under Single-Phase Open-Circuit Fault. IEEE Transactions on Industrial Electronics, 72(5), 4436-4446. https://doi.org/10.1109/tie.2024.3454474

Vancouver

Zhou Z, Li Z, Song C, Zhang G, Geng Q. Torque Ripple Suppression in the Full Torque Operation Range for Dual Three-Phase PMSM Under Single-Phase Open-Circuit Fault. IEEE Transactions on Industrial Electronics. 2025;72(5):4436-4446. doi:10.1109/tie.2024.3454474

BibTeX
@article{Zhou2025,
  author = {Zhou, Zhanqing and Li, Zhongchen and Song, Chenyi and Zhang, Guozheng and Geng, Qiang},
  title = {Torque Ripple Suppression in the Full Torque Operation Range for Dual Three-Phase PMSM Under Single-Phase Open-Circuit Fault},
  journal = {IEEE Transactions on Industrial Electronics},
  year = {2025},
  volume = {72},
  number = {5},
  pages = {4436--4446},
  doi = {10.1109/tie.2024.3454474}
}