An Improved Fault-Tolerant Method Based on Floating Capacitor Voltage Balance for Hybrid T 2 C-HB Converter
IEEE Transactions on Industrial Electronics · 2024-12 · 71 (12) · 15869-15880
DOI: 10.1109/tie.2024.3390747 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2024-12. Verfasst von Guangtao Zhou und 5 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong.
Abstract (Originalsprache)
Hybrid multilevel converters have gained more popularity due to their unique superiority. Thus, the T2C-HB converter is adopted in this article which consists a T-type converter (T2C) and three H-bridge (HB) cells. This hybrid converter combines the advantages of these two topologies and can output the same voltage level by adopting fewer switching devices compared with other multilevel converters. However, due to the high switching frequency of the HB switches, they may fail in practice which will cause serious deterioration in the output waveform and compromise the reliability of the entire system. Thus, a fault-tolerant control method based on floating capacitor voltage balance is proposed in this article. First, based on the level-shifted pulse width modulation (LS-PWM) method, the fault-tolerant control is accomplished by modifying the three-phase reference voltage. Second, a strategy which bypasses the HB equivalently when the absolute value of output voltage exceeds the peak value of the dc-link voltage is proposed to balance the floating capacitor voltage. Besides, the three-phase reference voltage is modified again utilizing the similar idea in order to balance the line voltage. Consequently, the line voltage remains unchanged during postfault operation and the floating capacitor voltage can restore balance without excessive fluctuation. Finally, the feasibility and correctness of the proposed method are verified by simulation and experimental results.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shandong
Zitieren
APA
Zhou, G., Xing, X., Du, C., Zhang, S., Zhang, R., & Chen, Z. (2024). An Improved Fault-Tolerant Method Based on Floating Capacitor Voltage Balance for Hybrid T 2 C-HB Converter. IEEE Transactions on Industrial Electronics, 71(12), 15869-15880. https://doi.org/10.1109/tie.2024.3390747
Vancouver
Zhou G, Xing X, Du C, Zhang S, Zhang R, Chen Z. An Improved Fault-Tolerant Method Based on Floating Capacitor Voltage Balance for Hybrid T 2 C-HB Converter. IEEE Transactions on Industrial Electronics. 2024;71(12):15869-15880. doi:10.1109/tie.2024.3390747
BibTeX
@article{Zhou2024,
author = {Zhou, Guangtao and Xing, Xiangyang and Du, Chunshui and Zhang, Shuai and Zhang, Rui and Chen, Zhiyuan},
title = {An Improved Fault-Tolerant Method Based on Floating Capacitor Voltage Balance for Hybrid T 2 C-HB Converter},
journal = {IEEE Transactions on Industrial Electronics},
year = {2024},
volume = {71},
number = {12},
pages = {15869--15880},
doi = {10.1109/tie.2024.3390747}
}
EUVIMED