EUVIMEDEUVIMED entdecken
Crossref

Detection of Field Coil Short-Circuit Fault in Synchronous Generators Based on Magnetic Bypass Shunt Effect

Yucai Wu, Xuanjie Fan, Lie Xu, Peng Qi, Weifu Lu

IEEE Transactions on Industrial Electronics · 2024-09 · 71 (9) · 11498-11507

DOI: 10.1109/tie.2023.3342311 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2024-09. Verfasst von Yucai Wu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Hebei Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The field coil short-circuit (FCSC) fault is a crucial factor that contributes to the severe vibration of the synchronous generators. The accurate detection of FCSC is of great significance as it facilitates a quicker confirmation and processing, and the key is to adopt a feasible real-time acquisition scheme for fault characteristics. According to the structural characteristics of the synchronous generator, we studied the magnetic bypass and shunt effect resulting from the structural components utilized to fix the stator core. A scheme of installing a magnetic flux detection coil on the back of the stator core of the synchronous generator was proposed. By analyzing the characteristic harmonics in the induced voltage of the detection coil, our proposed method is capable of detecting FCSC faults in the synchronous generator in real-time. A finite-element simulation model was established for a 334 MVA salient pole synchronous generator for method verification. The characteristic harmonic amplitudes of the induced voltages in the flux detection coil under different FCSC degrees were obtained. Also, several tests were conducted on a prototype synchronous generator with the type of MJF-30-6. The FCSC with varying fault degrees were simulated and the induced voltage signals of the flux detection coil were collected. Both simulation and test results validate our method in detecting the FCSC faults in synchronous generators. Additionally, our method also addresses the security concerns associated with sensor layout and offers a feasible solution for FCSC fault detection in synchronous generators.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Hebei Province

Zitieren

APA

Wu, Y., Fan, X., Xu, L., Qi, P., & Lu, W. (2024). Detection of Field Coil Short-Circuit Fault in Synchronous Generators Based on Magnetic Bypass Shunt Effect. IEEE Transactions on Industrial Electronics, 71(9), 11498-11507. https://doi.org/10.1109/tie.2023.3342311

Vancouver

Wu Y, Fan X, Xu L, Qi P, Lu W. Detection of Field Coil Short-Circuit Fault in Synchronous Generators Based on Magnetic Bypass Shunt Effect. IEEE Transactions on Industrial Electronics. 2024;71(9):11498-11507. doi:10.1109/tie.2023.3342311

BibTeX
@article{Wu2024,
  author = {Wu, Yucai and Fan, Xuanjie and Xu, Lie and Qi, Peng and Lu, Weifu},
  title = {Detection of Field Coil Short-Circuit Fault in Synchronous Generators Based on Magnetic Bypass Shunt Effect},
  journal = {IEEE Transactions on Industrial Electronics},
  year = {2024},
  volume = {71},
  number = {9},
  pages = {11498--11507},
  doi = {10.1109/tie.2023.3342311}
}