Novel Hotspot Temperature Prediction of Oil-Immersed Distribution Transformers: An Experimental Case Study
IEEE Transactions on Industrial Electronics · 2023-07 · 70 (7) · 7310-7322
DOI: 10.1109/tie.2022.3206690 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2023-07. Verfasst von Ali Abdali und 4 weiteren Autor:innen. Die Arbeit wurde bisher 51-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Kooshkan Transformer Company.
Abstract (Originalsprache)
Distribution transformers (DTs) are deemed fundamental and high-priced equipment for power grids, and their failure influences grid reliability. The continuity of DT operation highly depends on its insulation conditions and following that to the hotspot temperature (HST). In this article, a novel formula is proposed for HST prediction of DTs by considering the effective electrical and mechanical parameters on heat dissipation capacity. Additionally, complete and accurate 3D modeling based on computational fluid dynamics (CFD) is presented to validate the proposed novel formula for HST prediction. In this modeling, the conservator, which plays a key role in the HST value, is accurately modeled. Optical fiber sensors are utilized in the studied 500-kVA DT to verify the accuracy of the proposed HST prediction formula during the experimental temperature rise test. Experimental results show that the proposed formula is highly accurate and has an acceptable correlation with the empirical values. The root-mean-square error, mean error, and average error percentage (AEP) of the proposed formula are 0.3 °C, 0.3 °C, and 0.37%, respectively, in HST transient values, and 0.3 °C, 0.3 °C, and 0.29% in HST steady-state values, which substantiate the precision and proficiency of the proposed HST prediction formula rather than IEC and IEEE equations. Finally, a thermal camera is employed to verify the results of CFD-based 3D modeling in top-oil temperature, bottom-oil temperature, and conservator oil temperature during the experimental tests. According to the measurement results, temperatures of CFD-based 3D simulation and thermal camera in the aforementioned three points are in good agreement with each other and AEP is less than 1.4%, which indicates the accuracy and efficiency of the proposed 3-D modeling.
Förderung
- Kooshkan Transformer Company
Zitieren
APA
Abdali, A., Abedi, A., Mazlumi, K., Rabiee, A., & Guerrero, J. M. (2023). Novel Hotspot Temperature Prediction of Oil-Immersed Distribution Transformers: An Experimental Case Study. IEEE Transactions on Industrial Electronics, 70(7), 7310-7322. https://doi.org/10.1109/tie.2022.3206690
Vancouver
Abdali A, Abedi A, Mazlumi K, Rabiee A, Guerrero JM. Novel Hotspot Temperature Prediction of Oil-Immersed Distribution Transformers: An Experimental Case Study. IEEE Transactions on Industrial Electronics. 2023;70(7):7310-7322. doi:10.1109/tie.2022.3206690
BibTeX
@article{Abdali2023,
author = {Abdali, Ali and Abedi, Ali and Mazlumi, Kazem and Rabiee, Abbas and Guerrero, Josep M.},
title = {Novel Hotspot Temperature Prediction of Oil-Immersed Distribution Transformers: An Experimental Case Study},
journal = {IEEE Transactions on Industrial Electronics},
year = {2023},
volume = {70},
number = {7},
pages = {7310--7322},
doi = {10.1109/tie.2022.3206690}
}