EUVIMEDEUVIMED entdecken
Crossref

Full-Coverage Path Planning and Stable Interaction Control for Automated Robotic Breast Ultrasound Scanning

Ziwen Wang, Baoliang Zhao, Peng Zhang, Liang Yao, Qiong Wang, Bing Li, Max Q.-H. Meng, Ying Hu

IEEE Transactions on Industrial Electronics · 2023-07 · 70 (7) · 7051-7061

DOI: 10.1109/tie.2022.3204967 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2023-07. Verfasst von Ziwen Wang und 7 weiteren Autor:innen. Die Arbeit wurde bisher 69-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key-Area Research and Development Program of Guangdong Province, Regional Joint Fund of Guangdong.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasound examination is widely used for diagnosis of breast cancer, which requires a full-coverage scan of the whole organ and stable probe–breast interaction for high-quality image acquisition. In this study, a robotic system for automated breast ultrasound scanning is proposed. To avoid occlusion, point cloud of the breast is obtained from multiple angles and registered together for accurate tissue shape reconstruction, then scan path planning is performed with isometric 3-D point cloud searching algorithm for full and uniform coverage. To reduce the adverse influence of large tissue deformation during ultrasound scanning, a contact force–strain regression model is built for tissue deformation estimation and used as a feedforward to correct the planned scanning path, and a probe–tissue interaction model with scanning resistance is built for normal probe orientation adjustment. To maintain normal probe orientation and stable contact force during robotic ultrasound scanning, a hybrid force–velocity control framework is proposed based on admittance control algorithm. Experiment results show that the robotic system can successfully maintain a constant contact force and keep the probe's posture along the normal orientation of probe–breast interaction both in in-plane direction and out-of-plane direction.

Förderung

  • National Natural Science Foundation of China
  • Key-Area Research and Development Program of Guangdong Province
  • Regional Joint Fund of Guangdong
  • Shenzhen Science and Technology Program
  • CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems
  • Shenzhen Institute of Advanced Technology

Zitieren

APA

Wang, Z., Zhao, B., Zhang, P., Yao, L., Wang, Q., Li, B., Meng, M. Q., & Hu, Y. (2023). Full-Coverage Path Planning and Stable Interaction Control for Automated Robotic Breast Ultrasound Scanning. IEEE Transactions on Industrial Electronics, 70(7), 7051-7061. https://doi.org/10.1109/tie.2022.3204967

Vancouver

Wang Z, Zhao B, Zhang P, Yao L, Wang Q, Li B, et al. Full-Coverage Path Planning and Stable Interaction Control for Automated Robotic Breast Ultrasound Scanning. IEEE Transactions on Industrial Electronics. 2023;70(7):7051-7061. doi:10.1109/tie.2022.3204967

BibTeX
@article{Wang2023,
  author = {Wang, Ziwen and Zhao, Baoliang and Zhang, Peng and Yao, Liang and Wang, Qiong and Li, Bing and Meng, Max Q.-H. and Hu, Ying},
  title = {Full-Coverage Path Planning and Stable Interaction Control for Automated Robotic Breast Ultrasound Scanning},
  journal = {IEEE Transactions on Industrial Electronics},
  year = {2023},
  volume = {70},
  number = {7},
  pages = {7051--7061},
  doi = {10.1109/tie.2022.3204967}
}
Kostenlos starten →