Current-Source Inverter Fed Five-Phase PMSM Drives With Pentagon Stator Winding Considering SVM Scheme, Resonance Damping, and Fault Tolerance

Shijie Yang, Chengde Tong, Yi Sui, Zuosheng Yin, Ping Zheng

IEEE Transactions on Industrial Electronics · 2023-06 · 70 (6) · 5560-5570

DOI: 10.1109/tie.2022.3190848 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2023-06. Verfasst von Shijie Yang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 17 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Ministry of Industry and Information Technology of China, 2020 Industrial Internet Innovation and Development Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Current-source inverter (CSI) is considered as a promising candidate in the permanent magnet synchronous machine drive system, for its higher reliability and mitigated electromagnetic interference. In this article, the control scheme of CSI-fed five-phase machine drives with pentagon winding connection (PWC) is investigated. Filter capacitors are in parallel with each winding to bypass the pulsating current. The vector space distribution of PWC-CSI is presented which is different from that of star winding connection-CSI (SWC-CSI). A novel dual-plane space vector modulation is proposed to actively control the third harmonic component. To address the parallel resonance issue, the dual-loop current controller is adopted. Inner voltage loop is for resonance damping, whereas outer current loop is for current regulation. A precise s-domain model of current controller is built for the stability evaluation and parameter tuning. A comparative analysis between five-phase PWC-CSI and SWC-CSI is carried out. The PWC configuration can enhance the harmonic suppression, and exhibits lower dc-link voltage than SWC under the same condition. To explore the fault tolerant capability of PWC-CSI, the inverter single-phase open-circuit fault is analyzed and the post-fault current forms of four remaining healthy phases are recalculated. Experiments are performed to validate proposed schemes.

Förderung

  • National Natural Science Foundation of China
  • Ministry of Industry and Information Technology of China
  • 2020 Industrial Internet Innovation and Development Project
  • Natural Science Foundation of Heilongjiang Province

Zitieren

APA

Yang, S., Tong, C., Sui, Y., Yin, Z., & Zheng, P. (2023). Current-Source Inverter Fed Five-Phase PMSM Drives With Pentagon Stator Winding Considering SVM Scheme, Resonance Damping, and Fault Tolerance. IEEE Transactions on Industrial Electronics, 70(6), 5560-5570. https://doi.org/10.1109/tie.2022.3190848

Vancouver

Yang S, Tong C, Sui Y, Yin Z, Zheng P. Current-Source Inverter Fed Five-Phase PMSM Drives With Pentagon Stator Winding Considering SVM Scheme, Resonance Damping, and Fault Tolerance. IEEE Transactions on Industrial Electronics. 2023;70(6):5560-5570. doi:10.1109/tie.2022.3190848

BibTeX
@article{Yang2023,
  author = {Yang, Shijie and Tong, Chengde and Sui, Yi and Yin, Zuosheng and Zheng, Ping},
  title = {Current-Source Inverter Fed Five-Phase PMSM Drives With Pentagon Stator Winding Considering SVM Scheme, Resonance Damping, and Fault Tolerance},
  journal = {IEEE Transactions on Industrial Electronics},
  year = {2023},
  volume = {70},
  number = {6},
  pages = {5560--5570},
  doi = {10.1109/tie.2022.3190848}
}