EUVIMEDEUVIMED entdecken
Crossref

A Geometry-Guided Reconstruction Framework for Monocular Gastric Endoscopy in Medical Cyber-Physical Systems

Chengli Yang, Zipeng Zhang, Mengya Hu, Ziwei Wang, Ting Zhang, Dezheng Hua, Jinsong Chen, Xinhua Liu

IEEE Transactions on Industrial Cyber-Physical Systems · 2026 · 4 · 1179-1191

DOI: 10.1109/ticps.2026.3744311 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Industrial Cyber-Physical Systems, 2026. Verfasst von Chengli Yang und 7 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Open Fund of State Key Laboratory of Mechanical Transmission for Advanced Equipment, China Postdoctoral Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Capsule endoscopy serves as a perception front end in medical cyber-physical systems, where monocular reconstruction converts gastrointestinal observations into spatial representations for scene understanding and digital-twin-oriented analysis. However, weak texture, specular reflection, low illumination and limited viewpoint overlap in gastric scenes challenge correspondence estimation and pose stabilization, reducing reconstruction fidelity. To address this issue, we develop a geometry-guided reconstruction framework for monocular gastric endoscopy. First, an adaptive reprojection-based keyframe selection strategy is established to preserve informative observations for stable sparse reconstruction. Then, a shared-aggregation local feature Transformer (SALoFTR) together with iterative multi-view trajectory refinement and bundle adjustment improves correspondence robustness and reprojection-based geometric consistency under difficult gastric imaging conditions. Finally, a KAN-NeRF representation guided by refined sparse geometry generates gastric scene rendering results with improved visual fidelity. Experimental results showed that the proposed method achieves peak signal-to-noise ratios of 28.78, 30.40 and 31.52 dB on EndoSLAM, GastroHUN and a self-built capsule-robot dataset, respectively, while maintaining competitive structural similarity and perceptual quality. These results demonstrate the effectiveness under the evaluated datasets of the proposed framework for perception-oriented monocular gastric reconstruction in medical cyber-physical systems under the evaluated datasets.

Förderung

  • National Natural Science Foundation of China
  • Open Fund of State Key Laboratory of Mechanical Transmission for Advanced Equipment
  • China Postdoctoral Science Foundation
  • Postgraduate Research & Practice Innovation Program of Jiangsu Province
  • Graduate Innovation Program of China University of Mining and Technology

Zitieren

APA

Yang, C., Zhang, Z., Hu, M., Wang, Z., Zhang, T., Hua, D., Chen, J., & Liu, X. (2026). A Geometry-Guided Reconstruction Framework for Monocular Gastric Endoscopy in Medical Cyber-Physical Systems. IEEE Transactions on Industrial Cyber-Physical Systems, 4, 1179-1191. https://doi.org/10.1109/ticps.2026.3744311

Vancouver

Yang C, Zhang Z, Hu M, Wang Z, Zhang T, Hua D, et al. A Geometry-Guided Reconstruction Framework for Monocular Gastric Endoscopy in Medical Cyber-Physical Systems. IEEE Transactions on Industrial Cyber-Physical Systems. 2026;4:1179-1191. doi:10.1109/ticps.2026.3744311

BibTeX
@article{Yang2026,
  author = {Yang, Chengli and Zhang, Zipeng and Hu, Mengya and Wang, Ziwei and Zhang, Ting and Hua, Dezheng and Chen, Jinsong and Liu, Xinhua},
  title = {A Geometry-Guided Reconstruction Framework for Monocular Gastric Endoscopy in Medical Cyber-Physical Systems},
  journal = {IEEE Transactions on Industrial Cyber-Physical Systems},
  year = {2026},
  volume = {4},
  pages = {1179--1191},
  doi = {10.1109/ticps.2026.3744311}
}
Kostenlos starten →