Fachartikel in der Zeitschrift IEEE Transactions on Industrial Cyber-Physical Systems, 2026. Verfasst von Khwrwmdao Basumatary und 2 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ensuring PMU data integrity across the full acquisition-to-application pipeline is critical for Industrial Cyber-Physical Power Systems (ICPPS), yet no validated edge-deployable mechanism addresses anomaly detection and application-layer redundancy together. This paper proposes E dge-native D ata integrity and R edundancy A ssurance ( EDRA ), a framework grounded in a five-layer threat taxonomy (L1–L5) that classifies PMU data issues from device to application endpoint. EDRA integrates consensus-based anomaly detection in IEC 61131-3 ST on SEL-3530 and SEL-3350 RTACs within a deterministic 20 ms scan cycle with a Signal Conditioning and Outputting Block (SCOB) that takes the per-controller integrity flag ( CO_SOL ) and IEC 61850 LGOS subscription status as content-triggered fail-over signals, sustaining delivery to the application endpoint under a stated trust model. Validation on a Hardware-in-the-Loop testbed, against a reference derived from the injection command rather than from detector output, attains 80.6–99.3% precision and 77.4–99.5% recall across four use cases at up to 37.5% PMU compromise, with eight false alarms in 23,016 decisions under four non-attack power-system events. The SCOB restores Effective Data Availability (EDA) from none to 93–100% across four L3–L5 failure scenarios, transferring within 20.4 ms where content triggers it, and is deployed on an SEL-2240 Axion with 8% CPU utilisation. EDRA complies with IEEE C37.118, IEC 61131-3 and IEC 61850, consistent with IEEE C37.244-2013.

Zitieren

APA

Basumatary, K., Shukla, A., & Gonzalez-Longatt, F. (2026). Edge-Native PMU Data Integrity Assurance With Content-Triggered Application-Level Redundancy for Industrial Cyber-Physical Power Systems. IEEE Transactions on Industrial Cyber-Physical Systems, 4, 1275-1288. https://doi.org/10.1109/ticps.2026.3743459

Vancouver

Basumatary K, Shukla A, Gonzalez-Longatt F. Edge-Native PMU Data Integrity Assurance With Content-Triggered Application-Level Redundancy for Industrial Cyber-Physical Power Systems. IEEE Transactions on Industrial Cyber-Physical Systems. 2026;4:1275-1288. doi:10.1109/ticps.2026.3743459

BibTeX
@article{Basumatary2026,
  author = {Basumatary, Khwrwmdao and Shukla, Anup and Gonzalez-Longatt, Francisco},
  title = {Edge-Native PMU Data Integrity Assurance With Content-Triggered Application-Level Redundancy for Industrial Cyber-Physical Power Systems},
  journal = {IEEE Transactions on Industrial Cyber-Physical Systems},
  year = {2026},
  volume = {4},
  pages = {1275--1288},
  doi = {10.1109/ticps.2026.3743459}
}
Kostenlos starten →