EUVIMEDEUVIMED entdecken
Crossref

The Use of Line Impedance Symmetrical Components for Stator Faults Diagnostics in Symmetrical Six-Phase Induction Motors

Hugo R. P. Antunes, Davide S. B. Fonseca, Antonio J. Marques Cardoso

IEEE Transactions on Industry Applications · 2025-05 · 61 (3) · 3764-3773

DOI: 10.1109/tia.2025.3540985 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Industry Applications, 2025-05. Verfasst von Hugo R. P. Antunes und 2 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Portuguese Foundation for Science and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Open-loop control is widely utilized in industry due to its low cost and simplicity. However, this simplicity comes with a disadvantage: the generation of numerous harmonics in the motor currents that potentially interfere with the diagnostics process. Thus, this paper addresses the detection of incipient inter-turn short-circuit faults in symmetrical, six-phase, inverted-fed induction motors (S6PIM), controlled by a V/F scalar control. The fault diagnostics is conducted by applying a non-intrusive signal-based fault diagnostics technique based on the symmetrical components analysis of the line impedance. This technique allows the fault severity evaluation and the identification of the faulty motor phase, facilitating the implementation of fault-tolerant control strategies. The presented experimental results, for different load torques and fault scenarios, demonstrate the effectiveness of the proposed technique.

Förderung

  • Portuguese Foundation for Science and Technology

Zitieren

APA

Antunes, H. R. P., Fonseca, D. S. B., & Cardoso, A. J. M. (2025). The Use of Line Impedance Symmetrical Components for Stator Faults Diagnostics in Symmetrical Six-Phase Induction Motors. IEEE Transactions on Industry Applications, 61(3), 3764-3773. https://doi.org/10.1109/tia.2025.3540985

Vancouver

Antunes HRP, Fonseca DSB, Cardoso AJM. The Use of Line Impedance Symmetrical Components for Stator Faults Diagnostics in Symmetrical Six-Phase Induction Motors. IEEE Transactions on Industry Applications. 2025;61(3):3764-3773. doi:10.1109/tia.2025.3540985

BibTeX
@article{Antunes2025,
  author = {Antunes, Hugo R. P. and Fonseca, Davide S. B. and Cardoso, Antonio J. Marques},
  title = {The Use of Line Impedance Symmetrical Components for Stator Faults Diagnostics in Symmetrical Six-Phase Induction Motors},
  journal = {IEEE Transactions on Industry Applications},
  year = {2025},
  volume = {61},
  number = {3},
  pages = {3764--3773},
  doi = {10.1109/tia.2025.3540985}
}
Kostenlos starten →