Abstract (Originalsprache)
Electromagnetic interference is a potential cause of failure in all electronic devices. Immunity testing helps identify the frequencies at which these devices are more vulnerable, often termed weak spots. In biomedical instrumentation, where dependable operation is essential, such weak spots may still be excited by harsh and complex electromagnetic environments. One way to address this problem is to embed a frequency-selective detector that continuously monitors these weak spots and issues an early warning when potentially harmful disturbances occur. This article presents a proof-of-concept implementation in which a frequency-monitoring module based on a software-defined radio is integrated into a biosignals acquisition device. First, the weak spots of the acquisition device under test are identified using a “testing-to-failure” approach under controlled radiated immunity assessments. Next, a condition assessment framework for mission-critical systems is used to build a performance matrix that evaluates how reliably the integrated detector produces correct warnings and correct rejections when new electromagnetic disturbances are applied to the identified weak spots. The test signals are selected using a risk-based approach to represent worst-case scenarios for the detector. The evaluation on electrocardiograph signals reveals important tradeoffs in the hardware design and threshold configuration of the detector that should be considered when optimizing detection performance against electromagnetic disturbances. This work is distinguished by the integration of a frequency-selective detector into a biosignals acquisition device.
Förderung
- European Union's Horizon 2020 Research and Innovation Programme
Zitieren
APA
Xue, X., Gonzalez-Atienza, M., Nunes, T., Claeys, T., Gamboa, H., & Pissoort, D. (2026). Design and Evaluation of an SDR-Based Platform for Monitoring Electromagnetic Disturbances in a Biosignals Acquisition Device. IEEE Transactions on Electromagnetic Compatibility, 68(4), 813-824. https://doi.org/10.1109/temc.2026.3697853
Vancouver
Xue X, Gonzalez-Atienza M, Nunes T, Claeys T, Gamboa H, Pissoort D. Design and Evaluation of an SDR-Based Platform for Monitoring Electromagnetic Disturbances in a Biosignals Acquisition Device. IEEE Transactions on Electromagnetic Compatibility. 2026;68(4):813-824. doi:10.1109/temc.2026.3697853
BibTeX
@article{Xue2026,
author = {Xue, Xinting and Gonzalez-Atienza, Miriam and Nunes, Tiago and Claeys, Tim and Gamboa, Hugo and Pissoort, Davy},
title = {Design and Evaluation of an SDR-Based Platform for Monitoring Electromagnetic Disturbances in a Biosignals Acquisition Device},
journal = {IEEE Transactions on Electromagnetic Compatibility},
year = {2026},
volume = {68},
number = {4},
pages = {813--824},
doi = {10.1109/temc.2026.3697853}
}
EUVIMED