Radiation Detection Performance of Gamma Rays From Melt- and Solution-Grown Inorganic Perovskite CsPbBr 3 Semiconductor Detectors
IEEE Transactions on Electron Devices · 2026-08 · 73 (8) · 4986-4992
DOI: 10.1109/ted.2026.3695836 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Electron Devices, 2026-08. Verfasst von Bao Xiao und 8 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, China Postdoctoral Science Foundation.
Abstract (Originalsprache)
Perovskite CsPbBr 3 has emerged as a promising room-temperature semiconductor radiation detector, synthesizable via both melt- and solution-growth methods. Herein, we systematically compare the $\gamma $ -ray detection performance of CsPbBr 3 crystals grown by inverse temperature crystallization (ITC) and vertical Bridgman (VB) method. ITC-grown crystals exhibit relatively low optical transmittance of ~65%, a short photoluminescence (PL) lifetime of ~6.07 ns, moderate resistivity of $6.06\times 10^{{9}}~\Omega {\cdot }\text {cm}$ , and a limited on–off ratio of ~350. In contrast, VB-grown crystals show markedly improved optoelectronic properties, including higher transmittance (75%~80%), a much longer PL lifetime (~36.75 ns), higher resistivity ( $1.08\times 10^{{10}}~\Omega {\cdot }\text {cm}$ ), and a significantly enhanced on–off ratio (~5300). These improvements indicate higher crystal quality and reduced defect density in VB-grown CsPbBr 3 crystals, leading to more efficient charge transport. Notably, the average hole mobility and mobility-lifetime product increase from 5.36 cm ${}^{{2}}{\cdot }\text {V}^{-{1}}{\cdot }\text {s}^{-{1}}$ and $4.45\times 10^{-{4}}~\text {cm}^{{2}}{\cdot }\text {V}^{-{1}}$ to 24.87 cm ${}^{{2}}{\cdot }\text {V}^{-{1}}{\cdot }\text {s}^{-{1}}$ and $3.58\times 10^{-{3}}~\text {cm}^{2}{\cdot }\text {V}^{-{1}}$ , respectively. Accordingly, asymmetric Au/CsPbBr 3 /EGaIn detectors fabricated from VB-grown crystals deliver excellent average energy resolutions (ERs) of ~9.8% and ~5.5% for 241 Am and 57 Co $\gamma $ -ray sources, respectively, along with superior detector uniformity, whereas ITC-based detectors exhibit only moderate ERs of ~29.6% and ~22.6%. These results suggest that melt-grown CsPbBr 3 crystals are more favorable for high-performance $\gamma $ -ray detectors applications.
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
- China Postdoctoral Science Foundation
- Natural Science Foundation of Jiangsu Province
- Open Fund of the State Key Laboratory of Integrated Optoelectronics
- State Key Laboratory of Functional Crystals and Devices
- Undergraduate Training Program for Innovation and Entrepreneurship of Soochow University
Zitieren
APA
Xiao, B., Wang, Y., Qin, H., Chen, W., He, X., Du, J., Shen, N., Sun, Q., & He, Y. (2026). Radiation Detection Performance of Gamma Rays From Melt- and Solution-Grown Inorganic Perovskite CsPbBr 3 Semiconductor Detectors. IEEE Transactions on Electron Devices, 73(8), 4986-4992. https://doi.org/10.1109/ted.2026.3695836
Vancouver
Xiao B, Wang Y, Qin H, Chen W, He X, Du J, et al. Radiation Detection Performance of Gamma Rays From Melt- and Solution-Grown Inorganic Perovskite CsPbBr 3 Semiconductor Detectors. IEEE Transactions on Electron Devices. 2026;73(8):4986-4992. doi:10.1109/ted.2026.3695836
BibTeX
@article{Xiao2026,
author = {Xiao, Bao and Wang, Yuquan and Qin, Haoming and Chen, Wenjie and He, Xuchang and Du, Jun and Shen, Nannan and Sun, Qihao and He, Yihui},
title = {Radiation Detection Performance of Gamma Rays From Melt- and Solution-Grown Inorganic Perovskite CsPbBr 3 Semiconductor Detectors},
journal = {IEEE Transactions on Electron Devices},
year = {2026},
volume = {73},
number = {8},
pages = {4986--4992},
doi = {10.1109/ted.2026.3695836}
}